PAXDR000 Red Lion Controls, PAXDR000 Datasheet - Page 15

no-image

PAXDR000

Manufacturer Part Number
PAXDR000
Description
AC, Dual Rate, Upgradeable Red
Manufacturer
Red Lion Controls
Type
Rate/Totalizerr
Datasheet

Specifications of PAXDR000

Accuracy
± (0.01% of Input Signal Frequency)
Cut Out, Panel
3.62W x 1.77H Inches
Dimensions
3.80W x 1.95H Inches
Display Digit Height
.56 Inches
Display Type
LED Adjustable
Function
Rate/Totalizer
Input Type
Switch Selectable Pulse
Keypad Type
3 Programmable Function (5 Keys Total)
Number Of Digits
Rate = 5, Totalizer = 8
Primary Type
Electronic
Range, Measurement
Rate = 0 to 99999, Totalizer = ±99999999
Special Features
Programmable Function Keys
Termination
Cage Clamp
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
activated (maintained action).
(maintained action). This action only functions with a Setpoint card installed.


(maintained action). Internally the totalizer values continue to update.
configured as
When activated (momentary action), the meter resets the displays configured as
The meter inhibits the totalizer displays configured as
The meter deactivates the setpoints configured as
The meter performs a reset and inhibits the totalizer displays configured as





The meter holds (freeze) the displays configured as
When activated (momentary action), the meter deactivates the setpoints
TOTALIZER MAINTAINED (LEVEL) RESET AND INHIBIT

. (Momentary resets improve max. input frequencies over maintained resets.)
, as long as activated (maintained action).






DEACTIVATE SETPOINT MAINTAINED (LEVEL)
DEACTIVATE SETPOINT MOMENTARY (EDGE)
TOTALIZER MOMENTARY (EDGE) RESET

DISPLAY


DISPLAY


DISPLAY




DISPLAY




DISPLAY


DISPLAY


. This action only functions with a Setpoint card installed.
STORE TOTALIZER DISPLAY
TOTALIZER INHIBIT
Totalizer A
Totalizer B
Totalizer A
Totalizer B
Totalizer A
Totalizer B
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
Totalizer A
Totalizer B
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
FACTORY
FACTORY
FACTORY
FACTORY
FACTORY
FACTORY


















, as long as activated
, as long as activated






, as long as







15
15
activated (maintained action). This action only functions with a Setpoint plug-in
card installed.
(maintained action). This action only functions with a Setpoint card installed.
intensity level (1 of 4). The four levels correspond to Display Intensity Level
(
Input/ Function Key, is saved at power-down, so the meter will power-up at the
same intensity level.
configured as

The meter holds the state of the setpoints configured as
The meter activates the setpoints configured as
When activated (momentary action), the display intensity changes to the next


When activated (momentary action), the meter activates the setpoints





) settings of 0, 3, 8 & 15. The intensity level, when changed via the User

ACTIVATE SETPOINT MAINTAINED (LEVEL)
ACTIVATE SETPOINT MOMENTARY (EDGE)

CHANGE DISPLAY INTENSITY LEVEL
DISPLAY




DISPLAY




DISPLAY




. This action only functions with a Setpoint card installed.
HOLD SETPOINT STATE
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
DESCRIPTION
DESCRIPTION
DESCRIPTION
FACTORY
FACTORY
FACTORY













, as long as activated




, as long as






Related parts for PAXDR000