PAXDR000 Red Lion Controls, PAXDR000 Datasheet - Page 22

no-image

PAXDR000

Manufacturer Part Number
PAXDR000
Description
AC, Dual Rate, Upgradeable Red
Manufacturer
Red Lion Controls
Type
Rate/Totalizerr
Datasheet

Specifications of PAXDR000

Accuracy
± (0.01% of Input Signal Frequency)
Cut Out, Panel
3.62W x 1.77H Inches
Dimensions
3.80W x 1.95H Inches
Display Digit Height
.56 Inches
Display Type
LED Adjustable
Function
Rate/Totalizer
Input Type
Switch Selectable Pulse
Keypad Type
3 Programmable Function (5 Keys Total)
Number Of Digits
Rate = 5, Totalizer = 8
Primary Type
Electronic
Range, Measurement
Rate = 0 to 99999, Totalizer = ±99999999
Special Features
Programmable Function Keys
Termination
Cage Clamp
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
each time the setpoint value is reached. The automatic reset can occur at output
start (
appear if the Totalizer Setpoint Action is Timed Out. This reset may be different
from the Totalizer Reset Action selected in Module 4.
SELECTION
Assignment (
assigned totalizer is reset by a setpoint generated Totalizer Auto reset.






This parameter automatically resets the Setpoint Assigned Totalizer (A or B)
Select



) or output end (
LOW ACTING WITH NO DELAY
LOW ACTING WITH DELAY
SETPOINT RESET WITH DISPLAY RESET
ACTION
No Auto Reset
Reset to Zero at the Start of output activation.
Reset to Count Load Value at the Start of output activation
Reset to Zero at the End of output activation (timed out only)
Reset to Count Load at the End of output activation (timed out only)

, so the setpoint output will deactivate (reset) when the Setpoint


) totalizer display resets. Note: The output will not reset if the
TOTALIZER AUTO RESET


). The reset at output end selections will only




SETPOINT (ALARM) FIGURES FOR RATE


(For Reverse Action, The Alarm state is opposite.)
HIGH ACTING WITH NO DELAY
HIGH ACTING WITH DELAY
22
activates. (Example: SP1 deactivates when SP2 activates and SP4 when SP1
activates.) The last setpoint will wrap around to the first.

activates and then times out (deactivates). This function may only be used if the
SPn+1 is programmed for Setpoint Action of
when SP2 is activated and then times out.) The last setpoint will wrap around
to the first.

Select
Select
SETPOINT RESET WHEN SPn+1 DEACTIVATES


SETPOINT RESET WHEN SPn+1 ACTIVATES
, so the setpoint output will deactivate (reset) when SPn +1
, so the setpoint output will deactivate (reset) when SPn +1




LOW ACTING WITH TIMEOUT
HIGH ACTING WITH TIMEOUT



. (Example SP1 deactivates