4-2-9 Entering or Editing Programs
Programming Console Operations
00002
1, 2, 3...
When inputting a program for the first time, it is generally written to Program
Memory starting from address 000. Because this address appears when the
display is cleared, it is not necessary to specify it.
When inputting a program starting from other than 000 or to read or modify a
program that already exists in memory, the desired address must be desig-
nated.
This operation is used enter or edit programs. It is possible in PROGRAM mode
only.
The same procedure is used to either input a program for the first time or to
change a program that already exists. In either case, the current contents of
Program Memory is overwritten.
The program shown in the following diagram will be entered to demonstrate
this operation.
No
1. Press the CLR Key to bring up the initial display.
2. Input the desired address. It is not necessary to input leading zeroes.
3. Press the Down Arrow Key.
4. Press the Up and Down Arrow Keys to scroll through the program.
Pressing the MONTR Key will change to the I/O monitor display. Bits can be
force-set or force-reset from the I/O monitor display. Press the CLR Key to
return to I/O bit status monitoring of the initial address.
Note The ON/OFF status of any displayed bit will be shown if the PC is in
RUN
RUN or MONITOR mode.
C
2
MOV(021)
ADB(050)
DM 0000
#FFF6
#0100
LR 10
#0100
TIM 000
A
#0123
0
No
A
MONITOR
0
12.3 s
Address Instruction
00200
00201
00202
00203
OK
LD
TIM
MOV(021)
ADB(050)
PROGRAM
In the RUN or MONITOR
mode, ON/OFF status of
the bit will be displayed.
IR
LR
Operands
Section
DM 0000
#FFF6
00002
#0123
#0100
#0100
000
10
101
4-2