ETRX2HR-PA Telegesis Ltd, ETRX2HR-PA Datasheet - Page 27

MODULE

ETRX2HR-PA

Manufacturer Part Number
ETRX2HR-PA
Description
MODULE
Manufacturer
Telegesis Ltd
Datasheet

Specifications of ETRX2HR-PA

Module Applications
AMR, Building Automation, Wireless Sensor Network, M2M Industrial Controls
Mcu Supported Families
EM250
Processor Type
EM250
Wireless Protocol
IEEE 802.15.4
Data Rate
250Kbps
Module Interface
I2C, SPI, UART
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
16 Reliability Tests
The measurements were conducted after the module being exposed to room temperature and
humidity for 1 hour.
1
2
3
4
5
6
17 Application Notes
17.1 Safety Precautions
17.2 Design Engineering Notes
©2009 Telegesis (UK) Ltd
No
These specifications are intended to preserve the quality assurance of products as individual
components.
Before use, check and evaluate their operation when mounted on your products. Abide by
these specifications, without deviation when using the products. These products may short-
circuit. If electrical shocks, smoke, fire, and/or accidents involving human life are anticipated
when a short circuit occurs, then at least, provide the following failsafe functions, as a
minimum:
(1)
(2)
(1)
(2)
(3)
(4)
Vibration test
Shock test
Heat cycle test
Moisture test
Low temp. test
High temp. test
Ensure the safety of the whole system by installing a protection circuit and a protection
device.
Ensure the safety of the whole system by installing a redundant circuit or another
system to prevent a single fault causing an unsafe status.
Heat is the major cause of shortening the life of these products. Avoid assembly and
use of the target equipment in conditions where the product’s temperature may exceed
the maximum allowable.
Failure to do so may result in degrading of the product’s functions and damage to the
product.
If pulses or other transient loads (a large load applied in a short time) are applied to the
products, before use, check and evaluate their operation when assembled onto your
products.
These products are not intended for other uses, other than under the special conditions
shown below. Before using these products under such special conditions, check their
Item
Electrical parameter should be
in specification
the same as the above
the same as the above
the same as the above
the same as the above
the same as the above
Table 13. Reliability Tests
Limit
- 27 -
ETRX2PA Product Manual (Rev 1.07)
a) Freq.:10~50Hz,Amplitude:1.5mm
a) 20min. / cycle,1hrs. each of XYZ axis
b) Freq.:30~100Hz, 6G
b) 20min. / cycle,1hrs. each of XYZ axis
Dropped onto hard wood from height of
50cm for 3 times
-40°C for 30min. and +85°C for 30min.;
each temperature 300 cycles
+60°C, 90% RH, 300h
-40°C, 300h
+85°C, 300h
Condition
ETRX2PA