DS26514DK Maxim Integrated Products, DS26514DK Datasheet - Page 145

no-image

DS26514DK

Manufacturer Part Number
DS26514DK
Description
Power Management Modules & Development Tools 4-Port T1-E1-J1 Tran Transceiver Demo Kit
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS26514DK

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 4: Receive SLC-96 Synchronizer Enable (RSLC96). See Section
Bits 3 and 2: Out Of Frame Select Bits (OOF[2:1])
Bit 1: Receive RAI Integration Enable (RAIIE). The ESF RAI indication can be interrupted for a period not to
exceed 100ms per interruption (T1.403). In ESF mode, setting RAIIE will cause the RAI status from the DS26514
to be integrated for 200ms.
Bit 0: Receive-Side Remote Alarm Select (RRAIS)
Rev: 101608
OOF2
0
0
1
1
0 = The SLC-96 synchronizer is disabled.
1 = The SLC-96 synchronizer is enabled.
0 =
1 =
0 = Receive framer detects T1 remote alarm.
1 = Receive Framer detects J1 Remote Alarm.
OOF1
0
1
0
1
7
0
RAI detects when 16 consecutive patterns of 00FF appear in the FDL.
RAI clears when 14 or fewer patterns of 00FF hex out of 16 possible appear in the FDL.
RAI detects when the condition has been present for greater than 200ms.
RAI clears when the condition has been absent for greater than 200ms.
D4—Zeros in bit 2 of all channels.
ESF—00FF pattern in FDL.
D4—A one in the S-bit position of frame 12.
ESF—all ones in FDL.
OUT OF FRAME CRITERIA
2/4 frame bits in error
2/5 frame bits in error
2/6 frame bits in error
2/6 frame bits in error
T1RCR2 (T1 Mode)
Receive Control Register 2
014h + (200h x (n - 1)) : where n = 1 to 4
6
0
5
0
RSLC96
4
0
OOF2
3
0
9.9.4.4
DS26514 4-Port T1/E1/J1 Transceiver
for SLC-96 details.
OOF1
2
0
RAIIE
1
0
145 of 305
RRAIS
0
0

Related parts for DS26514DK