DS3112N+W Maxim Integrated Products, DS3112N+W Datasheet - Page 22

no-image

DS3112N+W

Manufacturer Part Number
DS3112N+W
Description
Network Controller & Processor ICs M13-E13-G.747 Mux an d T3-E3 Framer T3-E3
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3112N+W

Product
Framer
Number Of Transceivers
1
Data Rate
44.736 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
150 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Signal Name:
Signal Description:
Signal Type:
This signal will be forced high when the receive T3/E3 framer is in a Loss Of Signal (LOS) state. It will
remain high as long as the LOS state persists and will return low when the framer exits the LOS state. See
Section
software bit in the T3/E3 Status Register (Section 5.3).
Signal Name:
Signal Description:
Signal Type:
This signal will be forced high when the receive T3/E3 framer is in a Loss Of Frame (LOF) state. It will
remain high as long as the LOF state persists and will return low when the framer synchronizes. See
Section
software bit in the T3/E3 Status Register (Section 5.3).
Figure 2-1. T3/E3 Receive Framer Timing
FRCLK
Inverted Mode
FRCLK
Normal Mode
FRD
(see note)
FRDEN
Data Enable Mode for T3
(see note)
FRDEN
Data Enable Mode for E3
(see note)
FRDEN
Gapped Clock Mode for T3
(see note)
FRDEN
Gapped Clock Mode for E3
(see note)
FRSOF
(see note)
5.3
5.3
for details on the set and clear criteria for this signal. LOS status is also available via a
for details on the set and clear criteria for this signal. LOF status is also available via a
FRLOS
T3/E3 Receive Framer Loss Of Signal
Output
FRLOF
T3/E3 Receive Framer Loss Of Frame
Output
NOTE: FRD, FRDEN, AND FRSOF CAN BE INVERTED VIA MASTER CONTROL REGISTER 3.
22 of 133
Last Bit of
the Frame
T3: X1
E3: Bit 1 of FAS
DS3112

Related parts for DS3112N+W