TDA9109 STMicroelectronics, TDA9109 Datasheet - Page 17

no-image

TDA9109

Manufacturer Part Number
TDA9109
Description
Multimedia Misc DISC BY STM 11/99
Manufacturer
STMicroelectronics
Type
Low Cost Deflection Processorr
Datasheet

Specifications of TDA9109

Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
Through Hole
Package / Case
SPDIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA9109
Manufacturer:
ST
Quantity:
76
Part Number:
TDA9109
Manufacturer:
SAMSUNG
Quantity:
369
Part Number:
TDA9109
Manufacturer:
ST
0
Part Number:
TDA9109
Manufacturer:
ST
Quantity:
20 000
Part Number:
TDA9109-3
Manufacturer:
ST
Quantity:
6 266
Part Number:
TDA9109-4
Manufacturer:
SGS
Quantity:
6 219
Part Number:
TDA9109/N
Manufacturer:
PHI
Quantity:
6 218
Part Number:
TDA9109/S
Manufacturer:
ST
0
Part Number:
TDA9109A
Manufacturer:
ST
0
Part Number:
TDA9109A
Quantity:
650
OPERATING DESCRIPTION (continued)
I.6 - Sync Identification Status
The MCU can read (address read mode : 8D) the
status register via the I
sync priority depending on this status.
Among other data this register indicates the pres-
ence of sync pulses on H/HVIN, VSYNCIN and
(when 12V is supplied) whether a Vext has been
extracted from H/HVIN. Both horizontal and vertical
sync are detected even if only 5V is supplied.
In order to choose the right sync priority the MCU
may proceed as follows (see I
- refresh the status register,
- wait at least for 20ms (Max. vertical period),
- read this status register.
Sync priority choice should be :
Of course, when the choice is made, we can refresh
the sync detections and verify that the extracted
Vsync is present and that no sync type change has
occured. The sync processor also gives sync po-
larity information.
I.7 - IC status
The IC can inform the MCU about the 1st horizontal
PLL and vertical section status (locked or not) and
about the XRAY protection (activated or not).
Resetting the XRAY internal latch can be done
either by decreasing the V
directly resetting it via the I
I.8 - Sync Inputs
Both H/HVIN and VSYNCIN inputs are TTL com-
patible triggers with hysterisis to avoid erratic
detection. Both inputs include a pull up resistor
connected to V
I.9 - Sync Processor Output
The sync processor indicates on the HLOCKOUT
Pin whether 1st PLL is locked to an incoming
horizontal sync. HLOCKOUT is a TTL compatible
CMOS output. Its level goes to high when locked.
In the same time the D8 bit of the status register is
set to 0.
This information is mainly used to trigger safety
procedures (like reducing B+ value) as soon as a
Vext
Yes
det
No
H/V
Yes Yes
Yes
det
det
No
V
DD
Sync priority
Subaddress
.
03 (D8)
1
0
2
C bus, and then select the
2
C interface.
CC
2
C Address Table) :
Separated H & V
Composite TTL H&V
or V
Sync type
Comment
DD
supply or
change is detected on the incoming sync. Further
to this, it may be used in an automatic procedure
for free running frequency (f0) adjustment :
Sending the desired f0 on the sync input and
progressively decreasing the free running fre-
quency I
HLOCKOUT Pin will go high as soon as the proper
setting is reached.
Setting the free running frequency this way allows
to fully exploit the TDA9109/S horizontal frequency
range.
II - HORIZONTAL PART
II.1 - Internal Input Conditions
A digital signal (horizontal sync pulse or TTL
composite) is sent by the sync processor to the
horizontal input. It may be positive or negative
(see Figure 5).
Using internal integration, both signals are recog-
nized if Z/T < 25%. Synchronization occurs on the
leading edge of the internal sync signal. The mini-
mum value of Z is 0.7 s.
Figure 5
Another integration is able to extract the vertical
pulse from composite sync if the duty cycle is higher
than 25% (typically d = 35%) (see Figure 6).
Figure 6
The last feature performed is the removal of equali-
zation pulses to avoid parasitic pulses on the phase
comparator (which would be disturbed by missing
or extraneous pulses).
C
TRAMEXT
2
C register value (address 02), the
Z
Z
d
T
TDA9109/S
d
17/30