Adapter Selection
Entry Size
Determining the Wire
Bundle Size
The entry size of an adapter
is based on the size of the
wire bundle. If you don’t
know the size of the wire
bundle, measure a proto-
type or calculate the size.
Calculation of the wire bun-
dle size is based on three
values:
I
I
I
Instructions for calculating
these values follow.
COD Calculation
To calculate the cable out-
side diameter, first deter-
mine whether the wires in
the bundle are of the same
size or of different sizes.
COD Calculation for Wires of
the Same Size
For bundles with wires that
are all of the same size, fol-
low these steps:
1. Determine the number of
2. Find the multiplication
3. Find the wire diameter in
4. Multiply the wire diameter
Formula: D = Fd
Where:
D = Bundle diameter
F = Multiplication factor
d = Wire diameter
Cable outside diameter
(COD)
Cable jacket thickness
Jacketed cable diameter
wires in the wire bundle.
factor for that number in
Table E shown on the
next page.
the Wire and Cable sec-
tion (Section 9) of this
catalog.
(from Step 3) by the mul-
tiplication factor (from
Step 2) as shown below.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
D = 1.2
D = 1.2
D = 1.2
D = 1.2
D = 1.2 x 4.12
D = 4.95 mm
Example: A bundle of wires
containing 27 x 44A0111-22
F = 6.00 (the multiplication
d = 1.19 mm (.049 in)*
D = 6 x 1.19 mm (6 x .049
D = 7.14 mm (.294 in)
*Diameter of 44A0111-22 wire
obtained from the Wire and Cable
Section 9 of this catalog.
COD Calculation for Wires of
Different Sizes
To determine the wire bun-
dle diameter when using
wires of different sizes, fol-
low these steps:
1. Determine the number of
2. Find the diameter of the
3. Calculate the cable out-
Where:
D = Bundle diameter
N = Number of wires
d = Diameter of wires
Example: A bundle of wires
containing
3 x 44A0111-221* (1.192-
mm dia.)
5 x 44A0111-201* (1.42-mm
dia.)
1 x 44A0111-181* (1.65-mm
dia.)
*For wire information see the Wire
and Cable Section 9 of this catalog.
D = 1.2 N1d12 + N2d 22 + N3d32
wires in the wire bundle.
wires in the Wire and
Cable section of this cat-
alog.
side diameter by using
this formula:
factor for 27 wires from
Table E)
in)
3 x 1.192 + 5 x 1.42 + 1 x 1.65
3 x 1.4 + 5 x 2.02 + 1 x 2.7
4.2 + 10.1 + 2.7
17
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
2
2
2
South America: 55-11-3611-1514
Japan: 81-44-900-5102
Singapore: 65-4866-151
UK: 44-1793-528171

Related parts for 327913-000