HFIXF1110CC Intel, HFIXF1110CC Datasheet - Page 163

no-image

HFIXF1110CC

Manufacturer Part Number
HFIXF1110CC
Description
Manufacturer
Intel
Datasheet

Specifications of HFIXF1110CC

Number Of Transceivers
1
Screening Level
Commercial
Mounting
Surface Mount
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HFIXF1110CC.B3-998844
Manufacturer:
Cortina Systems Inc
Quantity:
135
Part Number:
HFIXF1110CC.B3-998844
Manufacturer:
Cypress
Quantity:
106
Part Number:
HFIXF1110CC.B3-998844
Manufacturer:
Cortina Systems Inc
Quantity:
10 000
8.5.6
Datasheet
Table 94. TX FIFO High Watermark Ports 0 to 9 ($ 0x600 - 0x609) (Sheet 1 of 2)
TX Block Register Overview
Table 94
include the TX FIFO High and Low Watermark.
TX FIFO High
Watermark Port 0
TX FIFO High
Watermark Port 1
TX FIFO High
Watermark Port 2
TX FIFO High
Watermark Port 3
TX FIFO High
Watermark Port 4
TX FIFO High
Watermark Port 5
TX FIFO High
Watermark Port 6
1. R = Read Only; CoR = Clear on Read; W = Write; R/W = Read/Write
2. For all TX FIFO High Watermark Registers, the following bit definitions apply to all ports (0:9):
Bits 31:13 - Reserved and R.
Bits 12:0 - Described above.
Name
through
2
Intel
®
IXF1110 10-Port 1000 Mbps Ethernet Media Access Controller
Table 100 on page 171
Description
High watermark for TX FIFO port 0. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
High watermark for TX FIFO port 1. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
High watermark for TX FIFO port 2. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
High watermark for TX FIFO port 3. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
High watermark for TX FIFO port 4. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
High watermark for TX FIFO port 5. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
High watermark for TX FIFO port 6. The default
value is 1584 bytes. When the amount of data
stored in the FIFO exceeds this value, the TX
FIFO indicates “SATISFIED.” This implies
further up in the system that no more data must
be sent to this port.
Order Number: 250210, Revision: 009
Intel
®
IXF1110 10-Port 1000 Mbps Ethernet Media Access Controller
provide an overview of the TX Block Registers, which
Address
0x600
0x601
0x602
0x603
0x604
0x605
0x606
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
1
0x00000630
0x00000630
0x00000630
0x00000630
0x00000630
0x00000630
0x00000630
07-Oct-2005
Default
163