HFIXF1110CC Intel, HFIXF1110CC Datasheet - Page 170

no-image

HFIXF1110CC

Manufacturer Part Number
HFIXF1110CC
Description
Manufacturer
Intel
Datasheet

Specifications of HFIXF1110CC

Number Of Transceivers
1
Screening Level
Commercial
Mounting
Surface Mount
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HFIXF1110CC.B3-998844
Manufacturer:
Cortina Systems Inc
Quantity:
135
Part Number:
HFIXF1110CC.B3-998844
Manufacturer:
Cypress
Quantity:
106
Part Number:
HFIXF1110CC.B3-998844
Manufacturer:
Cortina Systems Inc
Quantity:
10 000
Intel
07-Oct-2005
170
®
Table 98. TX FIFO Drain ($0x620) (Sheet 2 of 2)
Table 99. TX FIFO Info Out-of-Sequence ($ 0x621) (Sheet 1 of 2)
IXF1110 10-Port 1000 Mbps Ethernet Media Access Controller
Register Description: This register signals when out-of-sequence data is detected in the TX
FIFO. Events such as SOP followed by another SOP cause this bit to be set and remain so
until read. This register is cleared on Read.
1. R = Read Only; CoR = Clear on Read; W = Write; R/W = Read/Write
1. R = Read Only; CoR = Clear on Read; W = Write; R/W = Read/Write
31:10
Bit
Bit
5
4
3
2
1
0
9
8
7
6
Intel
TX FIFO Drain
Port 5
TX FIFO Drain
Port 4
TX FIFO Drain
Port 3
TX FIFO Drain
Port 2
TX FIFO Drain
Port 1
TX FIFO Drain
Port 0
Reserved
TX FIFO Info
Out-of-
Sequence Port 9
TX FIFO Info
Out-of-
Sequence Port 8
TX FIFO Info
Out-of-
Sequence Port 7
TX FIFO Info
Out-of-
Sequence Port 6
®
IXF1110 10-Port 1000 Mbps Ethernet Media Access Controller
Name
Name
Order Number: 250210, Revision: 009
Reserved
Port 9
0 = FIFO out-of-sequence event did not
1 = FIFO out-of-sequence event occurred
Port 8
0 = FIFO out-of-sequence event did not
1 = FIFO out-of-sequence event occurred
Port 7
0 = FIFO out-of-sequence event did not
1 = FIFO out-of-sequence event occurred
Port 6
0 = FIFO out-of-sequence event did not
1 = FIFO out-of-sequence event occurred
Port 5
0 = Disable TX FIFO drain mode
1 = Enable TX FIFO drain mode
Port 4
0 = Disable TX FIFO drain mode
1 = Enable TX FIFO drain mode
Port 3
0 = Disable TX FIFO drain mode
1 = Enable TX FIFO drain mode
Port 2
0 = Disable TX FIFO drain mode
1 = Enable TX FIFO drain mode
Port 1
0 = Disable TX FIFO drain mode
1 = Enable TX FIFO drain mode
Port 0
0 = Disable TX FIFO drain mode
1 = Enable TX FIFO drain mode
occur
occur
occur
occur
Description
Description
Type
Type
R/W
R/W
R/W
R/W
R/W
R/W
CoR
CoR
CoR
CoR
R
1
1
0x00000000
0x000000
Default
Default
Datasheet
0
0
0
0
0
0
0
0
0
0

Related parts for HFIXF1110CC