PIC18LF27J13T-I/SO Microchip Technology, PIC18LF27J13T-I/SO Datasheet - Page 353

no-image

PIC18LF27J13T-I/SO

Manufacturer Part Number
PIC18LF27J13T-I/SO
Description
28-pin, GP, 128KB Flash, 4KB RAM, 12 MIPS, 12-bit ADC 28 SOIC .300in T/R
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr
Datasheets

Specifications of PIC18LF27J13T-I/SO

Core Processor
PIC
Core Size
8-Bit
Speed
48MHz
Connectivity
I²C, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
22
Program Memory Size
128KB (64K x 16)
Program Memory Type
FLASH
Ram Size
3.8K x 8
Voltage - Supply (vcc/vdd)
2 V ~ 2.75 V
Data Converters
A/D 10x10b/12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
21.1.3
The Enhanced USART module supports the automatic
detection and calibration of baud rate. This feature is
active only in Asynchronous mode and while the WUE
bit is clear.
The automatic baud rate measurement sequence
(Figure 21-1) begins whenever a Start bit is received
and the ABDEN bit is set. The calculation is
self-averaging.
In the Auto-Baud Rate Detect (ABD) mode, the clock to
the BRG is reversed. Rather than the BRG clocking the
incoming RXx signal, the RXx signal is timing the BRG.
In ABD mode, the internal BRG is used as a counter to
time the bit period of the incoming serial byte stream.
Once the ABDEN bit is set, the state machine will clear
the BRG and look for a Start bit. The ABD must receive
a byte with the value, 55h (ASCII “U”, which is also the
LIN/J2602 bus Sync character), in order to calculate the
proper bit rate. The measurement is taken over both a
low and high bit time in order to minimize any effects
caused by asymmetry of the incoming signal. After a
Start bit, the SPBRGx begins counting up, using the pre-
selected clock source on the first rising edge of RXx.
After eight bits on the RXx pin, or the fifth rising edge, an
accumulated value totalling the proper BRG period is left
in the SPBRGHx:SPBRGx register pair. Once the 5
edge is seen (this should correspond to the Stop bit), the
ABDEN bit is automatically cleared.
If a rollover of the BRG occurs (an overflow from FFFFh
to 0000h), the event is trapped by the ABDOVF status
bit (BAUDCONx<7>). It is set in hardware by BRG roll-
overs and can be set or cleared by the user in software.
ABD mode remains active after rollover events and the
ABDEN bit remains set (Figure 21-2).
While calibrating the baud rate period, the BRG
registers are clocked at 1/8
rate. Note that the BRG clock can be configured by the
BRG16 and BRGH bits. The BRG16 bit must be set to
use both SPBRG1 and SPBRGH1 as a 16-bit counter.
This allows the user to verify that no carry occurred for
8-bit modes by checking for 00h in the SPBRGHx
register.
Refer to Table 21-4 for counter clock rates to the BRG.
While the ABD sequence takes place, the EUSART
state machine is held in Idle. The RCxIF interrupt is set
once the fifth rising edge on RXx is detected. The value
in the RCREGx needs to be read to clear the RCxIF
interrupt. The contents of RCREGx should be
discarded.
 2010 Microchip Technology Inc.
AUTO-BAUD RATE DETECT
th
the preconfigured clock
Preliminary
th
PIC18F47J13 FAMILY
TABLE 21-4:
21.1.3.1
Since the BRG clock is reversed during ABD acquisi-
tion, the EUSART transmitter cannot be used during
ABD. This means that whenever the ABDEN bit is set,
TXREGx cannot be written to. Users should also
ensure that ABDEN does not become set during a
transmit sequence. Failing to do this may result in
unpredictable EUSART operation.
BRG16
Note 1: If the WUE bit is set with the ABDEN bit,
0
0
1
1
2: It is up to the user to determine that the
3: To maximize baud rate range, it is recom-
BRGH
timing and communication baud rates
feature.
Auto-Baud Rate Detection will occur on
the byte following the Break character.
incoming character baud rate is within the
range of the selected BRG clock source.
Some combinations of oscillator frequency
and EUSART baud rates are not possible
due to bit error rates. Overall system
must be taken into consideration when
using the Auto-Baud Rate Detection
mended to set BRG16 bit if auto-baud
feature is used.
ABD and EUSART Transmission
0
1
0
1
BRG COUNTER
CLOCK RATES
BRG Counter Clock
F
F
F
F
OSC
OSC
OSC
OSC
DS39974A-page 353