DSCC FORM 2234
APR 97
(original equipment), design applications, and logistics purposes.
prepared specification or drawing.
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
application requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users
and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic
devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544.
(614) 692-0547.
MIL-PRF-38535, MIL-STD-1331, and as follows:
requirements are specified from the external system point of view. For example, address setup time would be shown as a
minimum since the system must supply at least that much time (even though most devices do not require it). On the other hand,
responses from the memory are specified from the device point of view. For example, the access time would be shown as a
maximum since the device never provides data later than that time.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor
6.1.2 Substitutability. Device class Q devices will replace device class M devices.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus (DSCC) when a system
6.4 Comments. Comments on this drawing should be directed to DSCC-VA , Columbus, Ohio 43218-3990, or telephone
6.5 Symbols, definitions, and definitions. The abbreviations, symbols, and definitions used herein are defined in
6.5.1 Timing limits. The table of timing values shows either a minimum or a maximum limit for each parameter. Input
C IN ......................................... Input terminal capacitance.
C OUT ..................................... Output terminal capacitance.
V SS ........................................ Ground zero voltage potential.
I CC ......................................... Supply current.
I IX .......................................... Input current.
I OZ ......................................... Output current.
T C .......................................... Case temperature.
V CC ....................................... Positive supply voltage.
DEFENSE SUPPLY CENTER COLUMBUS
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43218-3990
STANDARD
1/ The above parameter shall be recorded before and after the required
burn-in and life tests to determine the delta.
Parameter
I CC2
I IX
Table IIB. Delta limits at +25°C.
1/
+10% of specified value in
+10% of specified value in
Device types
SIZE
table I
table I
A
All
REVISION LEVEL
B
SHEET
5962-93144
25