Specifications of 804-1260

Battery Charger Type
Switch Mode
Battery Technologies Supported
Lead Acid
Supply Voltage
265VAC
Charge Current Max
60A
Configuring the Truecharge™ 2 Battery
Charger
Configuring the Charger Mode
Using the Onboard Display Panel
Figure 2-4 Onboard Display Panel
975-0402-01-01
This guide for use by qualified installers only
Once the charger is connected to a battery on bank 1 or to
AC, it is live and it may be configured. The indicator LEDs
on the onboard display will illuminate for a second (power on
test) before reporting charging and battery status information.
When the remote panel is connected, there will be a short
delay of about 15 seconds before reporting charging and
battery status information. The remote panel will use this
time to query the charger for the current operating conditions.
To configure the charger mode:
Note: By default, the Charger Mode is set to three-stage.
1. Press and hold the Charger Mode Select button for three
2. Select the proper charger mode.
seconds to advance to the next setting.
The LEDs will indicate which of the two modes is being
selected: three-stage (default) or two-stage.
Configuring the Truecharge™ 2 Battery Charger
2–27