804-1260 XANTREX TECHNOLOGY, 804-1260 Datasheet - Page 60
804-1260
Manufacturer Part Number
804-1260
Description
60A-12V TRUECHARGE 2 SERIES BATTERIE CHARGER XANTREX
Manufacturer
XANTREX TECHNOLOGY
Specifications of 804-1260
Battery Charger Type
Switch Mode
Battery Technologies Supported
Lead Acid
Supply Voltage
265VAC
Charge Current Max
60A
Specifications
DC Output Specifications
A–4
Number of isolated battery
bank outputs
DC output voltage range
including dead battery
charging voltage
Maximum equalization
voltage
Voltage accuracy (no load)
Nominal battery voltage
Normal operating output
range
Maximum DC output current
(total)
This guide for use by qualified installers only
TC1012:
1 output
TC1512:
2 separated outputs
TC2012, TC3012, TC4012, TC5012, TC6012,
TC1524, TC2024, TC3024, TC5024:
3 separated outputs
12 Vdc units: 0 – 15.5 Vdc
24 Vdc units: 0 – 31 Vdc
12 Vdc units: 16 Vdc
24 Vdc units: 32 Vdc
12 Vdc units:
±0.1 Vdc at 14.4 Vdc @ 25 °C (77 °F)
24 Vdc units:
±0.2 Vdc at 28.8 Vdc @ 25 °C (77 °F)
12 Vdc units:12 Vdc
24 Vdc units:24 Vdc
12 Vdc units: 0 – 16 Vdc
24 Vdc units: 0 – 32 Vdc
TC1012: 10 +10% A
TC1512: 15 +10% A
TC2012: 20 +10% A
TC3012: 30 +10% A
TC4012: 40 +10% A
TC5012: 50 +10% A
TC6012: 60 +10% A
TC1524: 15 +10% A
TC2024: 20 +10% A
TC3024: 30 +10% A
TC5024: 50 +10% A
975-0402-01-01