MAX197BENI+ Maxim Integrated Products, MAX197BENI+ Datasheet - Page 11

no-image

MAX197BENI+

Manufacturer Part Number
MAX197BENI+
Description
IC DAS 12BIT SNGL 28-DIP
Manufacturer
Maxim Integrated Products
Type
Data Acquisition System (DAS)r
Datasheet

Specifications of MAX197BENI+

Resolution (bits)
12 b
Sampling Rate (per Second)
100k
Data Interface
Parallel
Voltage Supply Source
Single Supply
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
28-DIP (0.300", 7.62mm)
Number Of Adc Inputs
8
Architecture
SAR
Conversion Rate
100 KSPs
Resolution
12 bit
Input Type
Voltage
Voltage Reference
Internal 4.096 V or External
Supply Voltage (max)
5 V
Maximum Power Dissipation
1143 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Input Voltage
10 V
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 6. Conversion Timing Using External Acquisition Mode
A standard interrupt signal, INT, is provided to allow the
device to flag the µP when the conversion has ended
and a valid result is available. INT goes low when con-
version is complete and the output data is ready
(Figures 5 and 6). It returns high on the first read cycle
or if a new control byte is written.
The MAX197 operates with either an internal or an
external clock. Control bits (D6, D7) select either inter-
nal or external clock mode. Once the desired clock
mode is selected, changing these bits to program
power-down will not affect the clock mode. In each
mode, internal or external acquisition can be used. At
power-up, external clock mode is selected.
Select internal clock mode to free the µP from the
burden of running the SAR conversion clock. To select
this mode, write the control byte with D7 = 0 and D6 = 1.
A 100pF capacitor between the CLK pin and ground
sets this frequency to 1.56MHz nominal. Figure 7
Single +5V, 12-Bit DAS with 8+4 Bus Interface
CS
D7–D0
INT
HBEN
DOUT
WR
RD
t
CSWS
______________________________________________________________________________________
t
DS
How to Read a Conversion
ACQMOD = "1"
t
t
CS
WR
CONTROL
BYTE
Multi-Range (±10V, ±5V, +10V, +5V),
Internal Clock Mode
t
t
CSHW
DH
Clock Modes
t
ACQI
ACQMOD = "0"
CONTROL
BYTE
t
CONV
shows a linear relationship between the internal clock
period and the value of the external capacitor used.
Figure 7. Internal Clock Period vs. Clock Pin Capacitance
t
D0
1500
1000
2000
500
0
t
0
CSRS
t
50
HIGH / LOW
BYTE VALID
INT1
CLOCK PIN CAPACITANCE (pF)
100 150 200
t
D01
HIGH / LOW
BYTE VALID
250
300
350
t
t
CSRH
TR
11