MAX197BENI+ Maxim Integrated Products, MAX197BENI+ Datasheet - Page 12

no-image

MAX197BENI+

Manufacturer Part Number
MAX197BENI+
Description
IC DAS 12BIT SNGL 28-DIP
Manufacturer
Maxim Integrated Products
Type
Data Acquisition System (DAS)r
Datasheet

Specifications of MAX197BENI+

Resolution (bits)
12 b
Sampling Rate (per Second)
100k
Data Interface
Parallel
Voltage Supply Source
Single Supply
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
28-DIP (0.300", 7.62mm)
Number Of Adc Inputs
8
Architecture
SAR
Conversion Rate
100 KSPs
Resolution
12 bit
Input Type
Voltage
Voltage Reference
Internal 4.096 V or External
Supply Voltage (max)
5 V
Maximum Power Dissipation
1143 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Input Voltage
10 V
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Select external clock mode by writing the control byte
with D7 = 0 and D6 = 0. Figure 8 shows CLK and WR
timing relationships in internal and external acquisition
modes, with an external clock. A 100kHz to 2.0MHz
Multi-Range (±10V, ±5V, +10V, +5V),
Single +5V, 12-Bit DAS with 8+4 Bus Interface
Figure 8a. External Clock and WR Timing (Internal Acquisition Mode)
Figure 8b. External Clock and WR Timing (External Acquisition Mode)
12
CLK
CLK
CLK
CLK
WR
WR
WR
WR
______________________________________________________________________________________
t
CWH
ACQMOD = "1"
ACQMOD = "1"
ACQMOD = "0"
ACQMOD = "0"
ACQUISITION STARTS
ACQUISITION STARTS
ACQUISITION STARTS
t
t
DH
DH
External Clock Mode
ACQUISITION STARTS
t
CWS
WR GOES HIGH WHEN CLK IS HIGH
WR GOES HIGH WHEN CLK IS LOW
WR GOES HIGH WHEN CLK IS LOW
WR GOES HIGH WHEN CLK IS HIGH
external clock with 45% to 55% duty cycle is required
for proper operation. Operating at clock frequencies
lower than 100kHz will cause a voltage droop across
the hold capacitor, and subsequently degrade perfor-
mance.
ACQUISITION ENDS
t
CWH
ACQUISITION ENDS
ACQMOD = "0"
ACQUISITION ENDS
ACQUISITION ENDS
ACQMOD = "0"
t
CWS
CONVERSION STARTS
CONVERSION STARTS
CONVERSION STARTS
CONVERSION STARTS

Related parts for MAX197BENI+