Specifications of EMC6D103S-CZC-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
SMSC EMC6D103
AVG2
01X (default)
0
0
0
1
AVG[2:0]
1XX
000
001
SFTR[7:5]
AVG1
X
Note: The default for the AVG[2:0] bits is ‘010’b.
To calculate conversion cycle timing for a given averaging mode:
Total Conversion Time = (TEMP_CONV)*96/(45kHz +/-10%)+ (VOLT_CONV)*68/(45kHz +/-10%)
Example: To calculate the nominal conversion time FOR AVG[2:0] = 001b.
Total Conversion Time = (TEMP_CONV)*96/(45kHz)+ (VOLT_CONV)*68/(45kHz)
Total Conversion Time = (16+16+1)*96/(45kHz)+ (5*1)*68/(45kHz)
Total Conversion Time = (33)*2.133ms+ (5)*1.511ms = ~78ms
Table 6.2
modes.
Note 6.1
Note 6.2
0
0
1
Compute total number of temperature conversions (TEMP_CONV)
Compute total number of voltage conversions (VOLT_CONV)
Calculate Time to complete all conversions is:
AVG0
(2x128)+(1x8)=264
TEMPERATURE
illustrates the min., nom., and max. conversion cycle timing for each of the four averaging
CONVERSIONS
(2x16)+(1x1)=33
X
X
0
1
The hardware monitor conversion clock is 45KHz ± 10%.
Temperature conversions take 96 clocks, each (2.133ms nom.); Voltage conversions take
68 clocks, each (1.511ms nom).
3x16=48
3x32=96
TOTAL
REMOTE
DIODE 1
128
16
16
32
Table 6.2 Conversion Cycle Timing
Table 6.1 AVG[2:0] Bit Decoder
REMOTE
DIODE 2
DATASHEET
128
CONVERSIONS
16
16
32
VOLTAGE
5x32=160
5x16=80
MEASUREMENTS PER READING
5x8=40
TOTAL
5x1=5
23
INTERNAL
DIODE
16
32
8
1
CONVERSION CYCLE TIME (MSEC)
(+2.5V, +5V, +12V, VCCP, AND VCC)
MIN.
567
203
406
71
ALL VOLTAGE READINGS
NOM.
624
223
447
78
16
32
Revision 0.3 (03-01-07)
8
1
MAX.
693
248
496
87

Related parts for EMC6D103S-CZC-TR