EMC6D103S-CZC-TR SMSC, EMC6D103S-CZC-TR Datasheet - Page 62

no-image

EMC6D103S-CZC-TR

Manufacturer Part Number
EMC6D103S-CZC-TR
Description
Industrial Temperature Sensors Auto Fan Contrllr Up to 4 Fans
Manufacturer
SMSC
Datasheet

Specifications of EMC6D103S-CZC-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Revision 0.3 (03-01-07)
8.2.11
Register
Address
BIT
0
1
2
3
4
5
6
7
42h
Diode 1 Limit
Diode 2 Limit
Sensor Limit
INT2 Event
Vccp_Error
2.5V_Error
VCC_Error
5V_Error
Remote
Remote
Internal
NAME
Active
Error
Error
Error
Read/
Write
8.10)
(See
Note
R-C
Register 42h: Interrupt Status Register 2
Note 8.10 This register is cleared on a read if no events are active.
This register is read only – a write to this register has no effect.
The Interrupt Status Register 2 bits is automatically set by the device whenever a remote temperature
sensor error occurs, a tach reading value is above the minimum value set in the tachometer minimum
registers, or whenever the 12V input voltage violates the limits set in the limit and parameter registers.
The Interrupt Status Register 2 register holds a set bit until the event is read by software or until the
individual interrupt enable bit is cleared.
This register holds a bit set until the event is read by software or until the individual enable bit is
cleared (see Note below). The contents of this register are cleared (set to 0) automatically by the
EMC6D103 after it is read by software, if the voltage no longer violate the limits set in the limit and
parameter registers, if the temperature sensor error no loner exists, or if the tach reading register is
no longer above the minimum. Once set, the Interrupt Status Register 2 bits remain set until a read
event occurs or until the individual interrupt enable bit is cleared, even if the voltage, Tach, or diode
event no longer exists.
Interrupt Status Register 2
R/W
Register Name
R
R
R
R
R
R
R
R
DEFAULT
Table 8.17 Register 42h: Interrupt Status Register 2
0
0
0
0
0
0
0
0
Table 8.16 Interrupt Status Register 1
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
The EMC6D103 automatically sets this bit to 1 when the 2.5V input
voltage is less than or equal to the limit set in the 2.5V Low Limit register
or greater than the limit set in the 2.5V High Limit register.
The EMC6D103 automatically sets this bit to 1 when the Vccp input
voltage is less than or equal to the limit set in the Vccp Low Limit register
or greater than the limit set in the Vccp High Limit register.
The EMC6D103 automatically sets this bit to 1 when the VCC input
voltage is less than or equal to the limit set in the VCC Low Limit register
or greater than the limit set in the VCC High Limit register.
The EMC6D103 automatically sets this bit to 1 when the 5V input voltage
is less than or equal to the limit set in the 5V Low Limit register or greater
than the limit set in the 5V High Limit register.
The EMC6D103 automatically sets this bit to 1 when the temperature
input measured by the Remote1- and Remote1+ is less than or equal to
the limit set in the Remote Diode 1 Low Temp register or greater than the
limit set in Remote Diode 1 High Temp register.
The EMC6D103 automatically sets this bit to 1 when the temperature
input measured by the internal temperature sensor is less than or equal
to the limit set in the Internal Low Temp register or greater than the limit
set in the Internal High Temp register.
The EMC6D103 automatically sets this bit to 1 when the temperature
input measured by the Remote2- and Remote2+ is less than or equal to
the limit set in the Remote Diode 2 Low Temp register or greater than the
limit set in the Remote Diode 1 High Temp register.
The device automatically sets this bit to 1 when a status bit is set in the
Interrupt Status Register 2.
(MSb)
ERR2
Bit 7
DATASHEET
ERR1
Bit 6
62
TACH4
Bit 5
TACH3
Bit 4
DESCRIPTION
TACH2
Bit 3
TACH1
Bit 2
Bit 1
RES
SMSC EMC6D103
(LSb)
Bit 0
12V
Datasheet
Default
Value
00h

Related parts for EMC6D103S-CZC-TR