EMC2303-1-KZ-TR SMSC, EMC2303-1-KZ-TR Datasheet - Page 15

no-image

EMC2303-1-KZ-TR

Manufacturer Part Number
EMC2303-1-KZ-TR
Description
Industrial Temperature Sensors RPM B Fan Controller w/HW Thermal Shutdwn
Manufacturer
SMSC
Datasheet

Specifications of EMC2303-1-KZ-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Fan Control Device with High Frequency PWM and Temperature Monitors
Datasheet
Chapter 5 SMBus Interface
SMSC EMC2300
5.1
ADDRESS
ENABLE#
1
0
0
Slave Address
The host processor communicates with the Fan Monitoring device through a series of read/write
registers via the SMBus interface. SMBus is a serial communication protocol between a computer host
and its peripheral devices.
The default Slave Address is 0101110b. If this address is desired, the designer should not ground the
Address Enable# pin and should not apply a strapping resistor to the Address Select pin.
If multiple devices are implemented in a system or another SMBus device requires address 0101110b,
TACH4 and PWM3 must be disabled. In this case, addressing is implemented as follows:
The board designer will apply a 10KΩ pull-down resistor to ground on the Address Enable# pin. Upon
power up, the
address according to the Address Select input. The device will latch the address during the first valid
SMBus transaction in which the first five bits of the targeted address match those of the
address. This feature eliminates the possibility of a glitch on the SMBus interfering with address
selection.
In this way, there can be up to three
devices can be used to monitor additional processors and temperature zones.
ADDRESS
SELECT
X
0
1
EMC2300
Address Enable# pulled to VCC through resistor
Note:
Address Enable# pulled to ground through 10kΩ
resistor
Address Select Pulled to ground through a 10kΩ
resistor
Address Enable# pulled to ground through 10kΩ
resistor
Address Select pulled to VCC through a 10kΩ
resistor
Table 5.1 SMBus Slave Address Options
device will be placed into Address Enable mode and assign itself an SMBus
Resistor value will be dependent on PWM
circuit implemented.
BOARD IMPLEMENTATION
DATASHEET
EMC2300
15
devices on the SMBus at any time. Multiple
SMBUS ADDRESS [7:1]
Revision 0.32 (06-23-08)
0101 100b
0101 101b
0101 110b
(default)
EMC2300
EMC2300

Related parts for EMC2303-1-KZ-TR