EMC2303-1-KZ-TR SMSC, EMC2303-1-KZ-TR Datasheet - Page 59

no-image

EMC2303-1-KZ-TR

Manufacturer Part Number
EMC2303-1-KZ-TR
Description
Industrial Temperature Sensors RPM B Fan Controller w/HW Thermal Shutdwn
Manufacturer
SMSC
Datasheet

Specifications of EMC2303-1-KZ-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Fan Control Device with High Frequency PWM and Temperature Monitors
Datasheet
SMSC EMC2300
8.2.12
8.2.13
Register
Address
Register
Address
5Ch
5Dh
54h
55h
56h
57h
58h
59h
5Ah
5Bh
5Eh
Read/
Read/
Write
Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Registers 54-5Bh: Fan Tachometer Low Limit
Setting the Lock bit has no effect on these registers.
The Fan Tachometer Low Limit registers indicate the tachometer reading that, if exceeded, the
corresponding bit will be set in the Interrupt Status Register 2 register. This register represents a
number of clock counts between the programmed number of tach edges and therefore as the number
increases, the effective RPM that it represents will decrease. The limit represents a fixed fan speed
(though the TACH measurement options may limit fan speeds that can be measured). See
Section 8.2.3
In Auto Fan Control mode, the fan can run at high speeds (100% duty cycle), so care should be taken
in software to ensure that the limit is low enough not to cause sporadic alerts. Note that an interrupt
status event will be generated when the tachometer reading is greater than the minimum tachometer
limit.
The fan tachometer will not cause a bit to be set in the interrupt status register if the current value in
the associated Current PWM Duty registers is 00h or if the PWM is disabled via the PWM
Configuration Register.
Interrupts will never be generated for a fan if its tachometer minimum is set to FFFFh.
Registers 5C-5Eh: PWM Configuration
These registers become read only when the Lock bit is set. Any further attempts to write to these
registers shall have no effect.
Bits [7:5] Zone/Mode
Bits [7:5] of the PWM Configuration registers associate each PWM with a temperature sensor.
PWM 1 Configuration
PWM 2 Configuration
PWM 3 Configuration
Register Name
Tach1 Minimum MSB
Tach2 Minimum MSB
Tach3 Minimum MSB
Tach4 Minimum MSB
Tach1 Minimum LSB
Tach2 Minimum LSB
Tach3 Minimum LSB
Tach4 Minimum LSB
for a description of the TACH data formatting.
Table 8.21 Registers 54-5Bh: Fan Tachometer Low Limit
Register Name
Table 8.22 Registers 5C-5Eh: PWM Configuration
(MSb)
ZON2
ZON2
ZON2
Bit 7
DATASHEET
(MSb)
Bit 7
15
15
15
15
7
7
7
7
ZON1
ZON1
ZON1
Bit 6
59
Bit 6
14
14
14
14
6
6
6
6
ZON0
ZON0
ZON0
Bit 5
Bit 5
13
13
13
13
5
5
5
5
Bit 4
INV
INV
INV
Bit 4
12
12
12
12
4
4
4
4
Bit 3
RES
RES
RES
Bit 3
11
11
11
11
3
3
3
3
SPIN2
SPIN2
SPIN2
Bit 2
Bit 2
10
10
10
10
2
2
2
2
SPIN1
SPIN1
SPIN1
Bit 1
Bit 1
Revision 0.32 (06-23-08)
1
9
1
9
1
9
1
9
SPIN0
SPIN0
SPIN0
(LSb)
(LSb)
Bit 0
Bit 0
0
8
0
8
0
8
0
8
Default
Default
Value
Value
FFh
FFh
FFh
FFh
FFh
FFh
FFh
FFh
62h
62h
62h

Related parts for EMC2303-1-KZ-TR