ISP1161ABD ST-Ericsson Inc, ISP1161ABD Datasheet - Page 100

no-image

ISP1161ABD

Manufacturer Part Number
ISP1161ABD
Description
IC USB HOST/DEVICE CTRLR 64-LQFP
Manufacturer
ST-Ericsson Inc
Datasheet

Specifications of ISP1161ABD

Controller Type
USB 2.0 Controller
Interface
Parallel
Voltage - Supply
3.3V, 5V
Current - Supply
47mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-1165
ISP1161ABD,157

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1161ABD
Manufacturer:
ROHM
Quantity:
2 747
Part Number:
ISP1161ABD
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1161ABD
Manufacturer:
PHI
Quantity:
1 000
Part Number:
ISP1161ABD
Manufacturer:
NXP
Quantity:
8 000
Part Number:
ISP1161ABD
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
ISP1161ABD-S
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1161ABD-T
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Philips Semiconductors
9397 750 13962
Product data
13.1.8 Reset Device (F6H)
13.2.1 Write/Read Endpoint Buffer (R/W: 10H,12H-1FH/01H–0FH)
13.2 Data flow commands
Table 89:
This command resets the ISP1161A DC in the same way as an external hardware
reset via input RESET. All registers are initialized to their ‘reset’ values.
Code (Hex): F6 — reset the device
Transaction — none
Data flow commands are used to manage the data transmission between the USB
endpoints and the system microprocessor. Much of the data flow is initiated via an
interrupt to the microprocessor. The data flow commands are used to access the
endpoints and determine whether the endpoint FIFOs contain valid data.
Remark: The IN buffer of an endpoint contains input data for the host, the OUT buffer
receives output data from the host.
This command is used to access endpoint FIFO buffers for reading or writing. First,
the buffer pointer is reset to the beginning of the buffer. Following the command, a
maximum of (M + 1) words can be written or read, with M given by (N + 1) DIV 2, N
representing the size of the endpoint buffer. After each read/write action the buffer
pointer is automatically incremented by 2.
In DMA access, the first word (the packet length) is skipped: transfers start at the
second word of the endpoint buffer. When reading, the ISP1161A DC can detect the
last word via the End of Packet (EOP) condition. When writing to a bulk/interrupt
endpoint, the endpoint buffer must be completely filled before sending the data to the
host. Exception: when a DMA transfer is stopped by an external EOT condition, the
current buffer content (full or not) is sent to the host.
Remark: Reading data after a Write Endpoint Buffer command or writing data after a
Read Endpoint Buffer command will cause unpredictable behavior of the ISP1161A
DC.
Code (Hex): 01 to 0F — write (control IN, endpoint 1 to 14)
Code (Hex): 10, 12 to 1F — read (control OUT, endpoint 1 to 14)
Transaction — write/read maximum (M + 1) words (isochronous endpoint: N ≤ 1023,
bulk/interrupt endpoint: N ≤ 32)
The data in the endpoint FIFO must be organized as shown in
of endpoint FIFO access is given
Bit
15 to 0
DcDMACounter register: bit description
Symbol
DMACR[15:0]
Rev. 03 — 23 December 2004
Description
DMA Counter register
Full-speed USB single-chip host and device controller
Table
91.
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
Table
ISP1161A
90. An example