ICS1893CKILF IDT, Integrated Device Technology Inc, ICS1893CKILF Datasheet - Page 62

PHYCEIVER LOW PWR 3.3V 56-MLF2

ICS1893CKILF

Manufacturer Part Number
ICS1893CKILF
Description
PHYCEIVER LOW PWR 3.3V 56-MLF2
Manufacturer
IDT, Integrated Device Technology Inc
Series
PHYceiver™r
Type
PHY Transceiverr
Datasheet

Specifications of ICS1893CKILF

Protocol
MII
Voltage - Supply
3.14 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
56-VQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
1893CKILF
800-1023

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS1893CKILF
Manufacturer:
IDT
Quantity:
206
Part Number:
ICS1893CKILFT
Manufacturer:
ST
Quantity:
785
Part Number:
ICS1893CKILFT
Manufacturer:
ICS
Quantity:
20 000
7.7.2 Acknowledge (bit 5.14)
7.7.3 Remote Fault (bit 5.13)
7.7.4 Technology Ability Field (bits 5.12:5)
7.7.5 Selector Field (bits 5.4:0)
ICS1893CF, Rev. K, 05/13/10
The ISO/IEC specification defines bit 5.14 as the Acknowledge bit. When this bit is a:
The ISO/IEC specification defines bit 5.13 as the Remote Fault bit. This bit is set based on the Link Control
Word received from the remote link partner. When this bit is a logic:
Note:
The Technology Ability Field (TAF) bits (bits 5.12:5) determine the specific abilities that the remote link
partner is advertising. These bits are set based upon the Link Code Word received from the remote link
partner during the auto-negotiation process. The ISO/IEC specification defines the TAF technologies in
Annex 28B.
The ISO/IEC specification reserves bits 5.12:10 for future use. When each of these reserved bits is:
IDT uses some reserved bits to invoke auxiliary functions. To ensure proper operation of the ICS1893CF,
an STA must maintain the default value of these bits. Therefore, IDT recommends that an STA always write
the default value of any reserved bits during all management register write operations.
The Selector Field bits indicate the technology or encoding that the remote link partner is using for the
Auto-Negotiation message. The ICS1893CF supports only IEEE Std. 802.3, represented by a value of
00001b in bits 5.4:0. The ISO/IEC standard defines the Selector Field technologies in Annex 28A.
Presently, the IEEE standard defines the following two valid codes:
Zero, it indicates that the remote link partner has not received the ICS1893CF Link Control Word.
One, it indicates to the ICS1893CF / STA that the remote link partner has acknowledged reception of the
ICS1893CF Link Control Word.
Zero, it indicates that the remote link partner detects a Link Fault.
One, it indicates to the ICS1893CF / STA that the remote link partner detects a Link Fault.
Read by an STA, the ICS1893CF returns a logic zero.
Written to by an STA, the STA must use the default value specified in this data sheet.
00001b (IEEE Std 802.3)
00010b (IEEE Std 802.9)
For more information about this bit, see
ICS1893CF Data Sheet - Release
Copyright © 2009, Integrated Device Technology, Inc.
All rights reserved.
62
Section 7.3.9, “Remote Fault (bit
Chapter 7 Management Register Set
1.4)”.
May, 2010

Related parts for ICS1893CKILF