ICS1893CKILF IDT, Integrated Device Technology Inc, ICS1893CKILF Datasheet - Page 80

PHYCEIVER LOW PWR 3.3V 56-MLF2

ICS1893CKILF

Manufacturer Part Number
ICS1893CKILF
Description
PHYCEIVER LOW PWR 3.3V 56-MLF2
Manufacturer
IDT, Integrated Device Technology Inc
Series
PHYceiver™r
Type
PHY Transceiverr
Datasheet

Specifications of ICS1893CKILF

Protocol
MII
Voltage - Supply
3.14 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
56-VQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
1893CKILF
800-1023

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS1893CKILF
Manufacturer:
IDT
Quantity:
206
Part Number:
ICS1893CKILFT
Manufacturer:
ST
Quantity:
785
Part Number:
ICS1893CKILFT
Manufacturer:
ICS
Quantity:
20 000
7.14 Register 19: Extended Control Register 2
ICS1893CF, Rev. K, 05/13/10
The Extended Control Register provides more refined control of the internal ICS1893CF operations.
Note:
1. For an explanation of acronyms used in
2. During any write operation to any bit in this register, the STA must write the default value to all
Table 7-21. Extended Control Register (register [0x13])
† The default is the state of this pin at reset.
19.15 Node Mode
19.14 Hardware/Software
19.13 Remote Fault
19.12 ICS reserved
19.11
19.10 ICS reserved
19.9
19.8
19.7
19.6
19.5
19.4
19.3
19.2
19.1
19.0
Bit
Reserved bits.
Mode
ICS reserved
AMDIX_EN
MDI_MODE
Twisted Pair Tri-State
Enable, TPTRI
ICS reserved
ICS reserved
ICS reserved
ICS reserved
ICS reserved
ICS reserved
Automatic 100Base-TX
Power Down
ICS1893CF Data Sheet - Release
Definition
Copyright © 2009, Integrated Device Technology, Inc.
Node mode
No faults detected
Read unspecified
Read unspecified
Read unspecified
See Table 7-22
See Table 7-22
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Hardware mode
Twisted Pair Signals
are not Tri-Stated or
No effect
Do not automatically
power down
When Bit = 0
All rights reserved.
Table
80
7-20, see
Repeater mode
Software mode
Remote fault
detected
Read unspecified
Read unspecified
Read unspecified
See Table 7-22
See Table 7-22
Twisted Pair
Signals are
Tri-Stated
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Power down
automatically
When Bit = 1
Chapter 1, “Abbreviations and
Chapter 7 Management Register Set
cess
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Ac-
RO
RO
RO
RO
SF
Acronyms”.
fault
De-
0
1
0
0
0
0
0
0
0
0
0
0
1
0
0
1
May, 2010
Hex
4
2
0
1

Related parts for ICS1893CKILF