PEB3086FV14XT Lantiq, PEB3086FV14XT Datasheet - Page 235

PEB3086FV14XT

Manufacturer Part Number
PEB3086FV14XT
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3086FV14XT

Control Interface
HDLC
Lead Free Status / Rohs Status
Supplier Unconfirmed
Figure 85
Parameter
IOM output data delay
IOM input data setup
IOM input data hold
FSC strobe delay
Strobe signal delay
BCL / FSC delay
Frame sync setup
Frame sync hold
Frame sync width
Note: Min. value in synchronous state, max. value in non-synchronous state. This
Data Sheet
results in a phase shift of FSC when the S-Bus gets activated, this is the FSC
signal is shifted by 135 ns. This applies only to TE mode.
DCL (I)
FSC (I)
DU/DD (I)
DU/DD (O)
SDS (O)
IOM-2 Timing (LT-S, LT-T, NT mode)
t
IIS
t
IIH
Symbol
t
t
t
t
t
t
t
t
t
IOD
IIS
IIH
FSD
SDD
BCD
FSS
FSH
FSW
235
t
FSS
t
FSH
min.
4
3
-135
20
30
40
t
t
SDD
t
IOD
FSS
t
FSW
t
Limit Values
FSH
Electrical Characteristics
Bit 0
max.
60
15
50
30
Bit 0
PEB 3086
ITT09680
2003-01-30
ISAC-SX
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns

Related parts for PEB3086FV14XT