LMV1088RL/NOPB National Semiconductor, LMV1088RL/NOPB Datasheet - Page 17

IC AMP AUDIO MONO AB MIC 36USMD

LMV1088RL/NOPB

Manufacturer Part Number
LMV1088RL/NOPB
Description
IC AMP AUDIO MONO AB MIC 36USMD
Manufacturer
National Semiconductor
Series
PowerWise®r
Type
Class ABr
Datasheet

Specifications of LMV1088RL/NOPB

Output Type
1-Channel (Mono)
Voltage - Supply
2.7 V ~ 5.5 V
Features
Differential Inputs, I²C, Microphone, Mute
Mounting Type
Surface Mount
Package / Case
36-MicroSMDxt
Amplifier Class
AB
No. Of Channels
2
Supply Voltage Range
2.7V To 5.5V
Load Impedance
10kohm
Operating Temperature Range
-40°C To +85°C
Amplifier Case Style
SMD
No. Of Pins
36
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Max Output Power X Channels @ Load
-
Other names
LMV1088RLTR
Automatic Calibration
The full automatic calibration should only be required once,
when the product containing the LMV1088 has completed
manufacture, and prior to application packaging. The product
containing the LMV1088 will be calibrated to the micro-
phones, the microphone spacings, and the acoustical prop-
erties of the final manufactured product containing the
LMV1088.
The compensation or calibration technology is achieved via
memory stored coefficients when the FFNS circuitry activates
the calibration sequence. The purpose of the calibration se-
quence is to choose the optimized coefficients for the FFNS
circuitry for the given microphones, spacing, and acoustical
environment of the product containing the LMV1088.
A basic calibration can be performed with a single 1kHz tone,
however to take full advantage of this calibration feature a
three tone calibration (See the section PERFORMING A
THREE TONE CALIBRATION) is preferred .
The automatic calibration process can be initiated from either
a digital interface CALIBRATE pin (CAL) or via the I
face.
The logic level at the PROGRAM ENABLE (PE) pin deter-
mines if the result of the calibration is volatile or permanent.
Note: When the I
AUTOMATIC CALIBRATION VIA I
To initiate the automatic calibration via the I
following procedure is required:
From the initial condition where PE is 'low' level
Bring PE to a 'high' level (enable EEprom write)
Write '1' into I
calibration
bit 0 is '0' before operating the CAL pin (default value for this bit).
When this bit is set '1' the calibration engine of the LMV1088 is started
and will remain active with a higher supply current than normal oper-
ation. The state of the calibration remains active until this bit is reset,
'0”. With the bit set the 'low' to' high' transfer of the CAL pin will be
ignored.
2
C is operated, make sure that register 'R' (address 0x12)
2
C register 'R' (address 0x12) bit 0 to start
2
C COMMAND
FIGURE 7. Automatic Calibration via I
FIGURE 6. Automatic Calibration via CAL pin
2
interface, the
2
C inter-
17
To make the result of the calibration permanent (stored in the
EEPROM) the PROGRAM ENABLE (PE) pin must be high
during the automatic calibration process.
AUTOMATIC CALIBRATION VIA CAL PIN
To initiate the automatic calibration via the CAL pin, the fol-
lowing procedure is required:
A tone may be applied prior to the rising of CAL and PE. Sig-
nals applied to the microphone inputs before rising of CAL
and PE are ignored by the calibration system.
A tone may be applied prior to the rising of CAL and PE. Sig-
nals applied to the microphone inputs before rising of CAL
and PE are ignored by the calibration system.
From the initial condition where both PE and CAL are at
'low' level
bring PE to a 'high' level (enable EEprom write)
bring CAL to a 'high' level to start Calibration
Apply Audio stimulus (single tone 1kHz or three tone
sequence as described in PERFORMING A THREE
TONE CALIBRATION)
Hold CAL 'high' for at least 770ms
Remove Audio stimulus
bring CAL to a 'low' level to stop Calibration
bring PE to a 'low' level (disable EEprom write)
Apply Audio stimulus (single tone 1kHz or three tone
sequence as described in PERFORMING A THREE
TONE CALIBRATION)
Wait at least 770ms
Remove Audio stimulus
Write '0' into I
Bring PE to a 'low' level (disable EEprom write)
2
C COMMAND
2
C to finish calibration
202130r1
202130r2
www.national.com