LMV1088RL/NOPB National Semiconductor, LMV1088RL/NOPB Datasheet - Page 21

IC AMP AUDIO MONO AB MIC 36USMD

LMV1088RL/NOPB

Manufacturer Part Number
LMV1088RL/NOPB
Description
IC AMP AUDIO MONO AB MIC 36USMD
Manufacturer
National Semiconductor
Series
PowerWise®r
Type
Class ABr
Datasheet

Specifications of LMV1088RL/NOPB

Output Type
1-Channel (Mono)
Voltage - Supply
2.7 V ~ 5.5 V
Features
Differential Inputs, I²C, Microphone, Mute
Mounting Type
Surface Mount
Package / Case
36-MicroSMDxt
Amplifier Class
AB
No. Of Channels
2
Supply Voltage Range
2.7V To 5.5V
Load Impedance
10kohm
Operating Temperature Range
-40°C To +85°C
Amplifier Case Style
SMD
No. Of Pins
36
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Max Output Power X Channels @ Load
-
Other names
LMV1088RLTR
Measurement Setup
Because of the nature of the calibration system it is not pos-
sible to predict the absolute gain in the two microphone
channels of the Far Field Noise Cancelling System. This is
because, after the calibration function has been operated, the
noise cancelling circuit will compensate for the difference in
gain between the microphones. In Noise Cancelling mode,
this can result in a final gain offset of max 3dB between the
gain set in the registers (RA[3:0] and RB[2:0]) and the actual
measured gain between input and output of the LMV1088.
After performing a calibration the frequency characteristic of
the microphone channels will be matched for the two micro-
phones. As a result of this matching there can be a slight slope
in the frequency characteristic in one or both amplifiers.
A-WEIGHTED FILTER
The human ear is sensitive for acoustic signals within a fre-
quency range from about 20Hz to 20kHz. Within this range
the sensitivity of the human ear is not equal for each frequen-
cy. To approach the hearing response, weighting filters are
introduced. One of those filters is the A-weighted filter.
The A-weighted filter is used in signal to noise measurements
and THD+N measurements, where the wanted audio signal
is compared to device noise and distortion.
21
The use of this filter improves the correlation of the measured
values to the way these ratios are perceived by the human
ear.
FIGURE 11. A-Weighted Filter
20213010
www.national.com