AT89LP51ED2 Atmel Corporation, AT89LP51ED2 Datasheet - Page 93

no-image

AT89LP51ED2

Manufacturer Part Number
AT89LP51ED2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89LP51ED2

Flash (kbytes)
64 Kbytes
Max. Operating Frequency
20 MHz
Cpu
8051-1C
Max I/o Pins
42
Spi
1
Twi (i2c)
1
Uart
1
Adc Channels
7
Adc Resolution (bits)
10
Adc Speed (ksps)
153.8
Sram (kbytes)
2.25
Eeprom (bytes)
4096
Self Program Memory
API
Operating Voltage (vcc)
2.4 to 5.5
Timers
4
Isp
SPI/OCD/UART
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89LP51ED2-20AAU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP51ED2-20AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89LP51ED2-20JU
Manufacturer:
Atmel
Quantity:
10 000
14.3
14.3.1
3714A–MICRO–7/11
Auto-Reload Mode
Up Counter
Timer 2 can be programmed to count up or down when configured in its 16-bit auto-reload
mode. This feature is invoked by the DCEN (Down Counter Enable) bit located in the SFR
T2MOD (see
count up. When DCEN is set, Timer 2 can count up or down, depending on the value of the
T2EX pin. A summary of the Auto-Reload behaviors is listed in
Table 14-5.
Figure 14-2
counts up to MAX and then sets the TF2 bit upon overflow. The overflow also causes the timer
registers to be reloaded with BOTTOM, the 16-bit value in RCAP2H and RCAP2L. If EXEN2 = 1,
a 16-bit reload can be triggered either by an overflow or by a 1-to-0 transition at external input
T2EX. This transition also sets the EXF2 bit. Both the TF2 and EXF2 bits can generate an inter-
rupt. The Timer 2 overflow rate for this mode is given in the following equation:
Note:
Figure 14-2. Timer 2 Diagram: Auto-Reload Mode (DCEN = 0)
DCEN
0
1
1
Auto-Reload Mode:
In Fast Mode, TPS applies only when the T2X2 bit in CKCON0 is set. TPS always
applies in Compatibility Mode, therefore setting T2X2 in Compatibility Mode will double
the timeout period.
DCEN = 0
CLK
shows Timer 2 automatically counting up when DCEN = 0. In this mode Timer 2
SYS
T2EX
Table
X
Summary of Auto-Reload Modes
0
1
÷TPS
14-4). Upon reset, the DCEN bit is set to 0 so that timer 2 will default to
Direction
Down
Up
Up
AT89LP51RD2/ED2/ID2 Preliminary
Time-out Period
Behavior
BOTTOM
MAX
BOTTOM
BOTTOM
MAX
MAX
=
65536
------------------------------------------------------------------------------ -
reload to BOTTOM
underflow to MAX
overflow to BOTTOM
TL2
{
RCAP2H RCAP2L
f
Table
SYS
TH2
,
14-5.
}
×
(
TPS
+
1
)
93