ATmega8HVA Atmel Corporation, ATmega8HVA Datasheet - Page 74

no-image

ATmega8HVA

Manufacturer Part Number
ATmega8HVA
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATmega8HVA

Flash (kbytes)
8 Kbytes
Pin Count
28
Max. Operating Frequency
4 MHz
Cpu
8-bit AVR
# Of Touch Channels
3
Hardware Qtouch Acquisition
No
Max I/o Pins
6
Ext Interrupts
3
Usb Speed
No
Usb Interface
No
Spi
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
6
Adc Resolution (bits)
12
Adc Speed (ksps)
1.9
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.5
Eeprom (bytes)
256
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-20 to 85
I/o Supply Class
1.8 to 9.0
Operating Voltage (vcc)
1.8 to 9.0
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Input Capture Channels
2
32khz Rtc
No
Calibrated Rc Oscillator
Yes
16. Timer/Counter0 and Timer/Counter1 Prescalers
16.1
16.1.1
16.1.2
74
Overview
ATmega8HVA/16HVA
Internal Clock Source
Prescaler Reset
Timer/Counter1 and Timer/Counter0 share the same prescaler module, but the Timer/Counters
can have different prescaler settings. The description below applies to both Timer/Counter1 and
Timer/Counter0.
The Timer/Counter can be clocked directly by the system clock (by setting the CSn2:0 = 1). This
provides the fastest operation, with a maximum Timer/Counter clock frequency equal to system
clock frequency (f
clock source. The prescaled clock has a frequency of either f
f
The prescaler is free running, i.e., operates independently of the Clock Select logic of the
Timer/Counter, and it is shared by Timer/Counter1 and Timer/Counter0. Since the prescaler is
not affected by the Timer/Counter’s clock select, the state of the prescaler will have implications
for situations where a prescaled clock is used. One example of prescaling artifacts occurs when
the timer is enabled and clocked by the prescaler (6 > CSn2:0 > 1). The number of system clock
cycles from when the timer is enabled to the first count occurs can be from 1 to N+1 system
clock cycles, where N equals the prescaler divisor (8, 64, 256, or 1024).
It is possible to use the prescaler reset for synchronizing the Timer/Counter to program execu-
tion. However, care must be taken if the other Timer/Counter that shares the same prescaler
also uses prescaling. A prescaler reset will affect the prescaler period for all Timer/Counters it is
connected to.
Figure 16-1. Prescaler for Timer/Counter
CLK_I/O
/1024.
PSRSYNC
Tn
clk
I/O
CLK_I/O
Synchronization
). Alternatively, one of four taps from the prescaler can be used as a
Clear
CSn0
CSn1
CSn2
CLK_I/O
clk
n
Tn
/8, f
CLK_I/O
/64, f
CLK_I/O
8024A–AVR–04/08
/256, or

Related parts for ATmega8HVA