M55800A Atmel Corporation, M55800A Datasheet - Page 125

no-image

M55800A

Manufacturer Part Number
M55800A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of M55800A

Flash (kbytes)
0 Kbytes
Pin Count
176
Max. Operating Frequency
33 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
58
Ext Interrupts
58
Usb Speed
No
Usb Interface
No
Spi
1
Uart
3
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
72
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
NO
External Bus Interface
1
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.3/5.0
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
No
Timer Counter Operating
Modes
Trigger
1354D–ATARM–08/02
Figure 45. Clock Control
Each Timer Counter channel can independently operate in two different modes:
The Timer Counter Operating Mode is programmed with the WAVE bit in the TC Mode
Register. In Capture Mode, TIOA and TIOB are configured as inputs. In Waveform
Mode, TIOA is always configured to be an output and TIOB is an output if it is not
selected to be the external trigger.
A trigger resets the counter and starts the counter clock. Three types of triggers are
common to both modes, and a fourth external trigger is available to each mode.
The following triggers are common to both modes:
The Timer Counter channel can also be configured to have an external trigger. In Cap-
ture Mode, the external trigger signal can be selected between TIOA and TIOB. In
Waveform Mode, an external event can be programmed on one of the following signals:
TIOB, XC0, XC1 or XC2. This external event can then be programmed to perform a trig-
ger by setting ENETRG in TC_CMR.
If an external trigger is used, the duration of the pulses must be longer than the system
clock (MCK) period in order to be detected.
Whatever the trigger used, it will be taken into account at the following active edge of the
selected clock. This means that the counter value may not read zero just after a trigger,
especially when a low frequency signal is selected as the clock.
Capture Mode allows measurement on signals
Waveform Mode allows wave generation
Software Trigger: Each channel has a software trigger, available by setting SWTRG
in TC_CCR.
SYNC: Each channel has a synchronization signal SYNC. When asserted, this
signal has the same effect as a software trigger. The SYNC signals of all channels
are asserted simultaneously by writing TC_BCR (Block Control) with SYNC set.
Compare RC Trigger: RC is implemented in each channel and can provide a trigger
when the counter value matches the RC value if CPCTRG is set in TC_CMR.
Selected
Counter
Clock
Clock
Q
R
S
Trigger
CLKSTA
Q
CLKEN
R
S
AT91X40 Series
Event
Stop
CLKDIS
Disable
Event
125