Register 074DH: RCFP Receive Aborted Packet Counter
RABR[15:0]
A write to any one of the RCFP performance monitor registers loads the registers with the current
counter value and resets the internal counter to 1 or 0. The counter reset value is dependent on if
there was a count event during the transfer of the count to the Receive Aborted Packet Counter
registers. The counter should be polled regularly to avoid saturation.
To allow for synchronization update with all other blocks, writing to register 0000H will initiate a
global performance counter update.
Bit
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
When POS mode is selected, the RABR[15:0] bits indicate the number of aborted packets
received during the last accumulation interval. This counter is held at value 0 when ATM
mode is selected.
Type
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Function
RABR[15]
RABR[14]
RABR[13]
RABR[12]
RABR[11]
RABR[10]
RABR[9]
RABR[8]
RABR[7]
RABR[6]
RABR[5]
RABR[4]
RABR[3]
RABR[2]
RABR[1]
RABR[0]
S/UNI-2488 Telecom Standard Product Datasheet
Default
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Released