IDT82P2282 Integrated Device Technology, Inc., IDT82P2282 Datasheet - Page 109

no-image

IDT82P2282

Manufacturer Part Number
IDT82P2282
Description
2 Channel T1/J1/E1 Transceiver
Manufacturer
Integrated Device Technology, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2282PF
Manufacturer:
IDT
Quantity:
355
Part Number:
IDT82P2282PF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2282PF8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2282PFG
Manufacturer:
HITACHI
Quantity:
1 452
Part Number:
IDT82P2282PFG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2282PFG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
IDT82P2282
4.5
mit Payload Control blocks, per-channel/per-timeslot indirect register is
accessed by using an indirect register access scheme.
4.5.1
is ‘0’;
specify the indirect register address;
the bit is ‘0’;
Table 81: Related Bit / Register In Chapter 4
Operation
ADDRESS[6:0]
In Receive CAS/RBS Buffer, Receive Payload Control and Trans-
The indirect register read access is as follows:
- Read the BUSY bit in the Access Status register to confirm the bit
- Write the Access Control register to initiate the read operation and
- Read the BUSY bit in the Access Status register again to confirm
TEMODE
FM[1:0]
R_OFF
T_OFF
BUSY
D[7:0]
T1/J1
RWN
Bit
INDIRECT REGISTER ACCESS SCHEME
-
INDIRECT REGISTER READ ACCESS
TPLC Access Status / RPLC Access Status / RCRB Access Status
TPLC Access Data / RPLC Access Data / RCRB Access Data
TPLC Access Control / RPLC Access Control
Transmit Configuration 0
Receive Configuration 0
/ RCRB Access Control
T1/J1 Or E1 Mode
Software Reset
Register
98
4.5.2
is ‘0’;
specify the indirect register address.
DUAL T1/E1/J1 LONG HAUL / SHORT HAUL TRANSCEIVER
- Read the indirect register data from the Access Data register.
An indirect register access request is completed within 4 µs.
The indirect register write access is as follows:
- Read the BUSY bit in the Access Status register to confirm the bit
- Write the Access Data register;
- Write the Access Control register to initiate the write operation and
An indirect register access request is completed within 4 µs.
INDIRECT REGISTER WRITE ACCESS
0CA, 1CA / 0CF, 1CF / 0D5, 1D5, 2D5, 3D5
0C8, 1C8 / 0CD, 1CD / 0D3, 1D3
0C9, 1C9 / 0CE, 1CE / 0D4, 1D4
Address (Hex)
020, 120
028, 128
022, 122
004
October 7, 2003

Related parts for IDT82P2282