AD1845 Analog Devices, AD1845 Datasheet - Page 14

no-image

AD1845

Manufacturer Part Number
AD1845
Description
Parallel-port 16-Bit Soundport Stereo Codec
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD1845JP
Manufacturer:
AD
Quantity:
5 510
Part Number:
AD1845JP
Manufacturer:
AD
Quantity:
1 000
Part Number:
AD1845JP
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD1845JP
Quantity:
13
Part Number:
AD1845JST
Manufacturer:
AD
Quantity:
2
Part Number:
AD1845JST
Manufacturer:
AD
Quantity:
164
Part Number:
AD1845JST
Manufacturer:
AD
Quantity:
1 000
Part Number:
AD1845JST
Manufacturer:
AD
Quantity:
1 000
Part Number:
AD1845JST
Manufacturer:
ADI
Quantity:
8 000
Part Number:
AD1845JST
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD1845JSTZ
Manufacturer:
SYNCMOS
Quantity:
12 000
Part Number:
AD1845TP
Quantity:
5
Part Number:
AD1845XP
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD1845
DIRECT CONTROL REGISTER DEFINITIONS
IXA4:0
TRD
MCE
INIT
Immediately after reset and once the AD1845 has left the INIT state, the initial value of this register will be “0100 0000 (40h).”
During AD1845 initialization, this register cannot be written and always reads “1000 0000 (80h).”
IXD7:0
During AD1845 initialization, this register cannot be written and always reads as “1000 0000 (80h).”
Index Address Register (ADR1:0 = 0)
Indexed Data Register (ADR1:0 = 1)
ADR1:0
ADR1:0
0
1
Index Address. These bits define the address of the AD1845 register accessed by the Indexed Data Register.
These bits are read/write. IXA4 is not active in MODE1. Always write 0 to this bit when using the AD1845 in
MODE1.
Transfer Request Disable. This bit, when set, causes DMA transfers to cease when the Interrupt Status (INT) bit
of the Status Register is set.
0
1
Mode Change Enable. This bit must be set whenever the current functional mode of the AD1845 is changed
where noted in the Indirect Control Registers 8, 9, 28 and 29. MCE must be cleared at the completion of the
desired register changes.
The DAC outputs are automatically muted when the MCE bit is set. After MCE is cleared, the DAC outputs will
be restored to the state specified by the LDM and RDM mute bits.
Both ADCs and DACs are automatically muted for 128 sample cycles after exiting the MCE state to allow the ref-
erence and all filters to settle. The ADCs will produce midscale values; the DACs’ analog output will be muted.
All converters are internally operating during these 128 sample cycles, and the AD1845 will expect playback data
and will generate (midscale) capture data. Note that the autocalibrate-in-progress (ACI) bit will be set on exiting
from the MCE state regardless of whether or not ACAL was set. ACI will remain HI for these 128 sample cycles,
allowing system software to poll this bit rather than count cycles.
Special sequences must be followed if autocalibrate (ACAL) is set during mode change enable. See the
“Autocalibration” section.
AD1845 Initialization. This bit is set when the AD1845 cannot respond to parallel bus cycles. This bit is
read-only.
Register.
Indexed Register Data. These bits contain the contents of the AD1845 register referenced by the Indexed Data
Transfers Enabled During Interrupt. PDRQ and CDRQ pin outputs are generated uninhibited by interrupts.
DMA Current Counter Register decrements with every sample period when either PEN or CEN are enabled.
Transfers Disabled By Interrupt. PDRQ and CDRQ pin outputs are generated only if INT bit is 0 (when
either PEN or CEN, respectively are enabled). Any pending playback or capture requests are allowed to
complete at the time when TRD is set. After pending requests complete, the data in the FIFO will be con-
sumed at the sample rate. Subsequently, the midscale inputs will be internally generated for the DACs if
the DACZ bit is set, otherwise, the previous valid sample will be repeated, and the ADC output buffer will
contain the last valid output. Clearing the sticky INT bit (or the TRD bit) will cause the resumption of
playback and/or capture requests (presuming PEN and/or CEN are enabled). The DMA Current Counter
Register will not decrement while both the TRD bit is set and the INT bit is a one. No over run or under
run error will be reported when transfers are disabled by INT.
Data 7
Data 7
IXD7
INIT
Data 6
Data 6
MCE
IXD6
Data 5
Data 5
TRD
IXD5
–14–
Data 4
Data 4
IXA4
IXD4
Data 3
Data 3
IXA3
IXD3
Data 2
Data 2
IXA2
IXD2
Data 1
Data 1
IXA1
IXD1
Data 0
Data 0
IXA0
IXD0
REV. B

Related parts for AD1845