nRF24LE1 Nordic VLSI, nRF24LE1 Datasheet - Page 35

no-image

nRF24LE1

Manufacturer Part Number
nRF24LE1
Description
Manufacturer
Nordic VLSI
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
nRF24LE1-017Q24-R
Quantity:
1 411
Part Number:
nRF24LE1-017Q24-R7
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-017Q32-R
Manufacturer:
NORDIC
Quantity:
1 534
Part Number:
nRF24LE1-017Q32-R7
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-DNQ24-R
Manufacturer:
NORDIC
Quantity:
3 500
Part Number:
nRF24LE1-F16Q32-R
Manufacturer:
VISHAY
Quantity:
50 000
Part Number:
nRF24LE1-F16Q32-R
0
Company:
Part Number:
nRF24LE1-F16Q32-R/E
Quantity:
20 000
Company:
Part Number:
nRF24LE1-F16Q32-T
Quantity:
100
Part Number:
nRF24LE1-F16Q48
Manufacturer:
OKI
Quantity:
2 850
Part Number:
nRF24LE1-F16Q48-R
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-O17Q24-R
Manufacturer:
NORDIC
Quantity:
34 661
Part Number:
nRF24LE1-O17Q24-R7
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-O17Q24-T
Manufacturer:
NORDIC
Quantity:
20 000
Company:
Part Number:
nRF24LE1-O17Q32
Quantity:
1 800
Part Number:
nRF24LE1-O17Q48
Manufacturer:
GENERAL
Quantity:
795
Part Number:
nRF24LE1D
Manufacturer:
INFINEON
Quantity:
67 000
nRF24LE1 Preliminary Product Specification
The PRX, using MultiCeiver™ and Enhanced ShockBurst™, receives packets from more than one PTX. To
ensure that the ACK packet from the PRX is transmitted to the correct PTX, the PRX takes the data pipe
address where it received the packet and uses it as the TX address when transmitting the ACK packet.
Figure 16.
defined as the pipe address, must be unique. On the PTX the TX_ADDR must be the same as the
RX_ADDR_P0 and as the pipe address for the designated pipe.
Only when a data pipe receives a complete packet can other data pipes begin to receive data. When mul-
tiple PTXs are transmitting to a PRX, the ARD can be used to skew the auto retransmission so that they
only block each other once.
3.4.9
This section describes the timing sequence of Enhanced ShockBurst™ and how all modes are initiated
and operated. The Enhanced ShockBurst™ timing is controlled through the Data and Control interface.
The RF Transceiver can be set to static modes or autonomous modes where the internal state machine
Revision 1.1
is an example of an address configuration for the PRX and PTX. On the PRX the RX_ADDR_Pn,
Enhanced ShockBurst
Figure 16. Example of data pipe addressing in MultiCeiver™
PTX1
PTX2
Addr Data Pipe 0 (RX_ADDR_P0): 0x7878787878
Addr Data Pipe 1 (RX_ADDR_P1): 0xB3B4B5B6F1
Addr Data Pipe 2 (RX_ADDR_P2): 0xB3B4B5B6CD
Addr Data Pipe 3 (RX_ADDR_P3): 0xB3B4B5B6A3
Addr Data Pipe 4 (RX_ADDR_P4): 0xB3B4B5B60F
Addr Data Pipe 5 (RX_ADDR_P5): 0xB3B4B5B605
Frequency Channel N
timing
PTX3
35 of 191
PRX
PTX4
PTX5
PTX6

Related parts for nRF24LE1