si4430 Silicon Laboratories, si4430 Datasheet - Page 126

no-image

si4430

Manufacturer Part Number
si4430
Description
Si4430 Ism Transceiver
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
si4430-A0-FM
Manufacturer:
SILICON
Quantity:
3 500
Part Number:
si4430-A0-FM
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Company:
Part Number:
si4430-A0-FM
Quantity:
12 590
Company:
Part Number:
si4430-A0-FM
Quantity:
12 590
Part Number:
si4430-B1-FM
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
si4430-B1-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
si44300BOY-T1-E3
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4430B
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY
Quantity:
12 500
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY
Quantity:
100 000
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY
Quantity:
220
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4430BDY-T1-E3
Quantity:
2 454
Company:
Part Number:
si4430BDY-T1-E3
Quantity:
500
Company:
Part Number:
si4430BDY-T1-E3
Quantity:
70 000
Part Number:
si4430BDY-T1-GE3
Manufacturer:
Vishay/Siliconix
Quantity:
33 919
Company:
Part Number:
si4430BDY-T1-GE3
Quantity:
70 000
Register 53h. PLL Tune Time
Si4430
The total settling time (cold start) of the PLL after the calibration can be calculated as T
Reset value = 01010010
Reset value = 01010100
Invalid preamble will be evaluated during this period: (invalid_preamble_Threshold x 4) x Bit Rate period.
126
Register 54h. PA Boost
Name
Name
Type
Type
Bit
7:3
2:0
7:6
5:2
Bit
Bit
Bit
1
0
pa_vbias_boost PA VBIAS Boost.
inv_pre_th[5:2] Invalid Preamble Threshold.
Reserved[7:6]
ldo_pa_boost
pllts[4:0]
Name
D7
D7
pllt0
Name
Reserved[7:6]
R/W
PLL Soft Settling Time (T
This register will set the settling time for the PLL from a previous locked frequency in
Tune mode. The value is configurable between 0 µs and 310 µs, in 10 µs intervals. The
default plltime corresponds to 100 µs. See formula above.
PLL Settling Time (T
This register will set the time allowed for PLL settling after the calibrations are completed.
The value is configurable between 0 µs and 70 µs, in 10 µs steps. The default pllt0 corre-
sponds to 20 µs. See formula above.
D6
D6
Reserved.
LDO PA Boost.
pllts[4:0]
D5
R/W
D5
O
Preliminary Rev. 0.4
).
D4
S
).
D4
inv_pre_th
R/W
D3
Function
Function
D3
D2
D2
ldo_pa_boost pa_vbias_boost
CS
R/W
D1
= T
R/W
pllt0
D1
S
+ T
O
.
R/W
D0
D0

Related parts for si4430