si4430 Silicon Laboratories, si4430 Datasheet - Page 97

no-image

si4430

Manufacturer Part Number
si4430
Description
Si4430 Ism Transceiver
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
si4430-A0-FM
Manufacturer:
SILICON
Quantity:
3 500
Part Number:
si4430-A0-FM
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Company:
Part Number:
si4430-A0-FM
Quantity:
12 590
Company:
Part Number:
si4430-A0-FM
Quantity:
12 590
Part Number:
si4430-B1-FM
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
si4430-B1-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
si44300BOY-T1-E3
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4430B
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY
Quantity:
12 500
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY
Quantity:
100 000
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY
Quantity:
220
Part Number:
si4430BDY-T1-E3
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
si4430BDY-T1-E3
Quantity:
2 454
Company:
Part Number:
si4430BDY-T1-E3
Quantity:
500
Company:
Part Number:
si4430BDY-T1-E3
Quantity:
70 000
Part Number:
si4430BDY-T1-GE3
Manufacturer:
Vishay/Siliconix
Quantity:
33 919
Company:
Part Number:
si4430BDY-T1-GE3
Quantity:
70 000
Register 17h. Wake-Up Timer Value 1
Register 18h. Wake-Up Timer Value 2
Register 19h. Low-Duty Cycle Mode Duration
Reset value = xxxxxxxx
Reset value = xxxxxxxx
Reset value = 00000001
Name
*Note: The period of the wake-up timer can be calculated as T
Name
*Note: The period of the wake-up timer can be calculated as T
Name
*Note: The period of the low-duty cycle ON time can be calculated as T
Type
Type
Type
Bit
Bit
Bit
7:0
7:0
7:0
Bit
Bit
Bit
as in the wake-up timer setting in "Register 14h. Wake-Up Timer Period 1".
wtm[15:8]
wtm[7:0]
ldc[7:0]
Name
Name
Name
D7
D7
D7
Wake Up Timer Current Mantissa (M) Value*.
Wake Up Timer Current Mantissa (M) Value*.
Low-Duty Cycle Mode Duration (LDC)*.
If enabled, the LDC will start together when the WUT is supposed to start, and the dura-
tion of the LDC is specified by the address 19h and the equation that goes with it. In order
for the LDC to work, the LDC value has to be smaller than the M value specified in regis-
ters 15h and 16h.
LDC = 0 is not allowed here. Write at least decimal 1.
D6
D6
D6
D5
D5
D5
Preliminary Rev. 0.4
D4
D4
D4
wtm[15:8]
wtm[7:0]
WUT
WUT
ldc[7:0]
R/W
R
R
= (4 x M x 2
= (4 x M x 2
Function
Function
Function
LDC_ON
D3
D3
D3
R
R
= (4 x LDC x 2
) / 32.768 ms.
) / 32.768 ms.
D2
D2
D2
R
) / 32.768 ms. R is the same
D1
D1
D1
Si4430
D0
D0
D0
97

Related parts for si4430