pcf8576d NXP Semiconductors, pcf8576d Datasheet - Page 18

no-image

pcf8576d

Manufacturer Part Number
pcf8576d
Description
Universal Lcd Driver For Low Multiplex Rates
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pcf8576dH
Quantity:
5
Part Number:
pcf8576dH
Manufacturer:
PHILIPS
Quantity:
885
Part Number:
pcf8576dH
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Company:
Part Number:
pcf8576dH
Quantity:
30
Part Number:
pcf8576dH/2,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
pcf8576dT
Manufacturer:
PHILIPS
Quantity:
10 000
Part Number:
pcf8576dT
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pcf8576dT/2
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pcf8576dT/2
0
Company:
Part Number:
pcf8576dT/2
Quantity:
14 000
Part Number:
pcf8576dU/2DA/2
Manufacturer:
ROHM
Quantity:
2 500
Part Number:
pcf8576dU/2DA/2
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pcf8576dU/2DA/2
0
Part Number:
pcf8576dU/DA/2
Manufacturer:
NXP
Quantity:
16 016
Part Number:
pcf8576dU/DA/2
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Philips Semiconductors
6.14
The input bank selector loads display data into the display
RAM in accordance with the selected LCD drive
configuration. The BANK SELECT command can be used
to load display data in bit 2 in static drive mode or in
bits 2 and 3 in 1 : 2 mode. The input bank selector
functions are independent of the output bank selector.
6.15
The PCF8576D has a very versatile display blinking
capability. The whole display can blink at a frequency
selected by the BLINK command. Each blink frequency is
a multiple integer value of the clock frequency; the ratio
between the clock frequency and blink frequency depends
on the blink mode selected, as shown in Table 3.
Table 3 Blinking frequencies
Note
1. Blink modes 0.5, 1 and 2 Hz, and nominal blink frequencies 0.5, 1 and 2 Hz correspond to an oscillator frequency
2004 Dec 22
Off
2 Hz
1 Hz
0.5 Hz
Universal LCD driver for low
multiplex rates
(f
CLK
Input bank selector
Blinker
) of 1536 Hz at pin CLK. The oscillator frequency range is given in Chapter 11.
BLINK MODE
f
---------- -
------------ -
1536
------------ -
3072
768
f
f
CLK
CLK
CLK
NORMAL OPERATING MODE
RATIO
18
An additional feature allows an arbitrary selection of LCD
segments to be blinked in the static and 1 : 2 drive modes.
This is implemented without any communication
overheads by the output bank selector which alternates
the displayed data between the data in the display RAM
bank and the data in an alternative RAM bank at the blink
frequency. This mode can also be implemented by the
BLINK command.
In the 1 : 3 and 1 : 4 drive modes, where no alternative
RAM bank is available, groups of LCD segments can be
blinked by selectively changing the display RAM data at
fixed time intervals.
The entire display can be blinked at a frequency other than
the nominal blink frequency by sequentially resetting and
setting the display enable bit E at the required rate using
the MODE SET command.
blinking off
2 Hz
1 Hz
0.5 Hz
NOMINAL BLINK FREQUENCY
Product specification
PCF8576D

Related parts for pcf8576d