ep1agx50d Altera Corporation, ep1agx50d Datasheet - Page 84

no-image

ep1agx50d

Manufacturer Part Number
ep1agx50d
Description
Arria Gx Device Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep1agx50dF1152C4N
Manufacturer:
ALTERA
0
Part Number:
ep1agx50dF1152C5N
Manufacturer:
ALTERA
Quantity:
885
Part Number:
ep1agx50dF1152C5N
Manufacturer:
ALTERA
0
Part Number:
ep1agx50dF1152C6N
Manufacturer:
ALTERA
Quantity:
246
Part Number:
ep1agx50dF1152C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep1agx50dF1152C6N
Manufacturer:
ALTERA
0
Part Number:
ep1agx50dF1152C6N
Manufacturer:
ALTERA
Quantity:
4
Part Number:
ep1agx50dF1152I4N
Manufacturer:
ALTERA
0
Part Number:
ep1agx50dF1152I5N
Manufacturer:
ALTERA
Quantity:
648
Part Number:
ep1agx50dF780C6
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
ep1agx50dF780C6N
Manufacturer:
ALTERA
Quantity:
852
Digital Signal Processing Block
2–76
Arria GX Device Handbook, Volume 1
The DSP block is divided into four block units that interface with four
LAB rows on the left and right. Each block unit can be considered one
complete 18 × 18-bit multiplier with 36 inputs and 36 outputs. A local
interconnect region is associated with each DSP block. Like a LAB, this
interconnect region can be fed with 16 direct link interconnects from the
LAB to the left or right of the DSP block in the same row. R4 and C4
routing resources can access the DSP block’s local interconnect region.
The outputs also work similarly to LAB outputs as well. Eighteen outputs
from the DSP block can drive to the left LAB through direct link
interconnects and 18 can drive to the right LAB though direct link
interconnects. All 36 outputs can drive to R4 and C4 routing
interconnects. Outputs can drive right- or left-column routing.
Altera Corporation
May 2008