z80189 ZiLOG Semiconductor, z80189 Datasheet - Page 147

no-image

z80189

Manufacturer Part Number
z80189
Description
Z80180, Z8s180, Z8l180 Mpu Operation
Manufacturer
ZiLOG Semiconductor
Datasheet
132
ASCI Control Register B 0 (CNTLB0: 02H)
ASCI Control Register B 1 (CNTLB1: 03H)
UM005003-0703
Bit
Bit/Field
R/W
Reset
Note: R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W
7
6
Z8018x
Family MPU User Manual
MPBT
MP
MPBT
R/W
7
X
R/W
R/W
R/W
MP
6
0
Value
CTS/PS
R/W
5
0
Description
Multiprocessor Bit Transmit — When multiprocessor
communication format is selected (MP bit is 1), MPBT is
used to specify the MPB data bit for transmission. If
MPBT is 1, then MPB = 1 is transmitted. If MPBT is 0,
then MPBT = 0 is transmitted. MPBT state is undefined
during and after RESET.
Multiprocessor Mode — When MP is set to 1, the data
format is configured for multiprocessor mode based on
the MOD2 (number of data bits) and MOD0 (number of
stop bits) bits in CNTLA. The format is as follows.
Start bit + 7 or 8 data bits + MPB bit + 1 or 2 stop bits
Multiprocessor (MP = 1) format has no provision for
parity. If MP is 0, the data format is based on MOD0
MOD1, MOD2, and may include parity. The MP bit is
cleared to 0 during RESET.
R/W
PE0
4
0
R/W
DR
3
0
R/W
SS2
2
1
R/W
SS1
1
1
R/W
SS0
0
1

Related parts for z80189