Ed. 2, May 2001
T1Fx8
TXC-03108
TXC-03108-MA
SELECTED PARAMETER VALUES
ABSOLUTE MAXIMUM RATINGS AND ENVIRONMENTAL LIMITATIONS
Notes: 1. Conditions exceeding the Min or Max values may cause permanent failure. Exposure to conditions near the Min
THERMAL CHARACTERISTICS
POWER REQUIREMENTS
Supply voltage
DC input voltage
Storage temperature range
Ambient Operating Temperature
Moisture Exposure Level
Relative Humidity, during assembly
Relative Humidity
ESD Classification
LATCH-UP
208-lead BGA thermal resis-
tance: junction to ambient
256-lead BGA thermal resis-
tance: junction to ambient
V
I
P
I
P
DD
DD
DD
DD
DD
(outputs loaded)
(outputs loaded)
(outputs loaded)
(outputs loaded)
2. Pre-assembly storage in non-drypack conditions is not recommended. Please refer to the instructions on the
3. Absolute value tested per MIL-STD-883D, Method 3015.7.
Parameter
or Max values for extended periods may impair device reliability.
"CAUTION" label on the drypack bag in which devices are supplied.
Parameter
Parameter
Proprietary TranSwitch Corporation Information for use Solely by its Customers
3.15
Min
Min
Symbol
270
TECHNICAL OVERVIEW
3.30
Typ
220
82
67
ESD
V
V
ME
RH
RH
LU
T
T
DD
1
IN
A
S
1
Typ
140
485
- 16 of 24 -
Max
3.45
2
2
Absolute value 2000
Min
-0.3
-0.5
-55
-40
30
5
Unit
mW
mW
mA
mA
Max
38.0
25.0
V
1. All channels operating.
2. All channels operating.
Max
+3.9
150
100
5.5
85
60
Output load 30 pF.
SYSCI at 16 MHz. Transmission, MVIP
or Data Mode.
Output load 30 pF.
SYSCI at 25 MHz.
H-MVIP Mode.
All channels powered down (lead
PWDN low). Output load 30 pF. SYSCI
at 16 MHz.
o
o
Unit
C/W
C/W
Level
Unit
Test Conditions
o
o
%
%
V
V
V
0 ft/min linear airflow
0 ft/min linear airflow
C
C
Test Conditions
0 ft/min linear airflow
Meets JEDEC STD-
JESD22-A112-A
non-condensing
per EIA/JEDEC
See Note 3.
Conditions
Note 1
Note 1
Note 1
Note 2
78