ssd1329 ETC-unknow, ssd1329 Datasheet - Page 26

no-image

ssd1329

Manufacturer Part Number
ssd1329
Description
128 X 128 Oled Segment / Common Driver With Controller Equips With 16 Gray Scale Levels And 64 Hard Icon Lines
Manufacturer
ETC-unknow
Datasheet
Note
(1]
(2)
(3)
(4)
(Display Startline=0)
Please refer to Table 9-1 for the details of setting command “Set Re-map”A0h.
The “Display Start Line” is set by the command “Set Display Start Line” A1h and please refer to Table for the setting
details
The “Column Start/End Address” is set by the command “Set Column Address” 15h and please refer to Table 9-1 for
the setting details
The “Row Start/End Address” is set by the command “Set Row Address” 75h and please refer to Table 9-1 for the
setting details
Solomon Systech
Command “Set Re-map” A0h is set to :
Display Start Line=00h
Column Start Address=01h
Column End Address=3Eh
Row Start Address=01h
Row End Address=7Eh
Data byte sequence: D0, D1, D2 … D7811
COM126
COM127
Outputs
COM0
COM1
COM
|
Address
(HEX)
Row
7E
7F
00
01
|
Table 8-9 shows the GDDRAM map under the following condition:
SEG0
00
Disable Column Address Re-map
Disable Nibble Re-map
Enable Horizontal Address Increment (A[2]=0)
Disable COM Re-map
SEG1
Table 8-9 : GDDRAM Address Map 5
D7750[3:0] D7750[7:4]
D0[3:0]
SEG2
01
D0[7:4]
SEG3
|
D7811[3:0] D7811[7:4]
SEG124
D61[3:0]
Dec 2005 P 26/58
3E
(A[1]=0)
(A[4]=0)
(A[0]=0)
SEG125
D61[7:4]
Nibble Re-map A[1]=0
SEG126
3F
Rev 1.1
SEG127
SSD1329
Column Address
SEG Outputs
(HEX)

Related parts for ssd1329