T-8110L AGERE [Agere Systems], T-8110L Datasheet - Page 30

no-image

T-8110L

Manufacturer Part Number
T-8110L
Description
Manufacturer
AGERE [Agere Systems]
Datasheet
Ambassador T8110L H.100/H.110 Switch
5 Operating Control and Status
Overall T8110L operational control and status is configured via registers occupying 0x00100—0x001FC in the
address space.
5.1 Control Registers
General control functions are soft reset, reset configuration, overall master output enables, and data memory con-
figuration. Clocking-specific general control functions are clock register access configuration, phase alignment,
clock fallback, and clock watchdog configuration.
Table 15. Control Register Map
5.1.1 Reset Registers
The soft reset and reset select registers control soft reset functions and reset signal masking. Writes to the soft
reset register trigger the corresponding action, and the set bit(s) are automatically cleared.
!
!
Soft resets are maskable via reset select register, SRBEB, and selectable via soft reset register, SRESR.
!
!
!
!
30
Address
0x0010C
DWORD
(20 Bits)
0x00100
0x00104 Phase alignment select
0x00108 Fallback trigger, upper
0x00114
Power-on reset: nonmaskable:
— At power-on, initialize all T8110L registers (including reset select register) and connection valid flags. The
Hard reset: maskable via reset select register, HRBEB:
— On assertion of RESET#, initialize all T8110L registers (excluding reset select register) and connection valid
Soft reset 1: Initialize all T8110L registers (excluding reset select register) and connection valid flags.
Soft reset 2: Initialize all T8110L registers (excluding reset select register).
Soft reset 3: Reset all interrupt pending registers and the interrupt in-service register.
Soft reset 4: Reset the interrupt in-service register only.
power-on reset cell test input is controlled via diagnostic register; see Section 11.
flags.
Watchdog EN, upper
Master enable
Reserved
Byte 3
Fallback trigger, lower
Failsafe threshold low
Clock register access
Watchdog EN, lower
Reserved
Byte 2
select
Register
Data memory mode select
Failsafe enable and status
Fallback type select
Watchdog select,
Reset select
NETREF
Byte 1
Watchdog select, C8
Agere Systems Inc.
Fallback control
Failsafe control
February 2004
Soft reset
Byte 0

Related parts for T-8110L