S9S08SG8E2VTG Freescale Semiconductor, S9S08SG8E2VTG Datasheet - Page 170

no-image

S9S08SG8E2VTG

Manufacturer Part Number
S9S08SG8E2VTG
Description
8-bit Microcontrollers - MCU 9S08 UC W/ 8K 0.25UM SGF
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S08SG8E2VTG

Rohs
yes
Core
S08
Processor Series
MC9S08SG8
Data Bus Width
8 bit
Maximum Clock Frequency
40 MHz
Program Memory Size
8 KB
Data Ram Size
8 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 5.5 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
TSSOP-16
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
12
Interface Type
SCI, SPI
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
16
Number Of Timers
2
Program Memory Type
Flash
Supply Voltage - Max
5.5 V
Supply Voltage - Min
2.7 V
Inter-Integrated Circuit (S08IICV2)
For example, if the bus speed is 8 MHz, the table below shows the possible hold time values with different
ICR and MULT selections to achieve an IIC baud rate of 100 kbps.
166
MULT
Field
ICR
7–6
5–0
IIC Multiplier Factor. The MULT bits define the multiplier factor, mul. This factor, along with the SCL divider,
generates the IIC baud rate. The multiplier factor mul as defined by the MULT bits is provided below.
00 mul = 01
01 mul = 02
10 mul = 04
11 Reserved
IIC Clock Rate. The ICR bits are used to prescale the bus clock for bit rate selection. These bits and the MULT
bits determine the IIC baud rate, the SDA hold time, the SCL Start hold time, and the SCL Stop hold time.
Table 11-5
The SCL divider multiplied by multiplier factor mul generates IIC baud rate.
SDA hold time is the delay from the falling edge of SCL (IIC clock) to the changing of SDA (IIC data).
SCL start hold time is the delay from the falling edge of SDA (IIC data) while SCL is high (Start condition) to the
falling edge of SCL (IIC clock).
SCL stop hold time is the delay from the rising edge of SCL (IIC clock) to the rising edge of SDA
SDA (IIC data) while SCL is high (Stop condition).
MULT
provides the SCL divider and hold values for corresponding values of the ICR.
0x2
0x1
0x1
0x0
0x0
SCL Start hold time = bus period (s)
SCL Stop hold time = bus period (s)
Table 11-4. Hold Time Values for 8 MHz Bus Speed
SDA hold time = bus period (s)
MC9S08SG8 MCU Series Data Sheet, Rev. 7
Table 11-3. IICF Field Descriptions
0x0B
0x00
0x07
0x14
0x18
ICR
IIC baud rate
3.500
2.500
2.250
2.125
1.125
SDA
=
Description
-------------------------------------------- -
mul
bus speed (Hz)
SCLdivider
mul
mul
mul
Hold Times (s)

SCL Start
SDA hold value
SCL Start hold value
SCL Stop hold value
3.000
4.000
4.000
4.250
4.750
SCL Stop
5.500
5.250
5.250
5.125
5.125
Freescale Semiconductor
Eqn. 11-1
Eqn. 11-2
Eqn. 11-3
Eqn. 11-4

Related parts for S9S08SG8E2VTG