EVAL-ADXL350Z-S Analog Devices, EVAL-ADXL350Z-S Datasheet - Page 15

no-image

EVAL-ADXL350Z-S

Manufacturer Part Number
EVAL-ADXL350Z-S
Description
Daughter Cards & OEM Boards EB
Manufacturer
Analog Devices
Series
ADXL350r
Datasheet

Specifications of EVAL-ADXL350Z-S

Rohs
yes
Product
Satellite Boards
Description/function
3 axis accelerometer evaluation board
Interface Type
I2C, SPI
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
2 V to 3.6 V
Factory Pack Quantity
1
For Use With
ADXL350
Data Sheet
POWER SAVINGS
Power Modes
The
in proportion to its output data rate, as outlined in Table 7. If
additional power savings is desired, a lower power mode is
available. In this mode, the internal sampling rate is reduced,
allowing for power savings in the 12.5 Hz to 400 Hz data rate
range but at the expense of slightly greater noise.
To enter lower power mode, set the LOW_POWER bit (Bit 4) in
the BW_RATE register (Address 0x2C). The current consumption
in low power mode is shown in Table 8 for cases where there is
an advantage for using low power mode. The current consump-
tion values shown in Table 7 and Table 8 are for a V
Current scales linearly with V
Table 7. Current Consumption vs. Data Rate
(T
Output Data
Rate (Hz)
3200
1600
800
400
200
100
50
25
12.5
6.25
A
= 25°C, V
ADXL350
S
automatically modulates its power consumption
= 2.5 V, V
Bandwidth (Hz)
1600
800
400
200
100
50
25
12.5
6.25
3.125
DD I/O
S
.
= 1.8 V)
Rate Code
1111
1110
1101
1100
1011
1010
1001
1000
0111
0110
S
of 2.5 V.
I
145
100
145
145
145
145
100
65
55
40
DD
(µA)
Rev. 0 | Page 15 of 36
Table 8. Current Consumption vs. Data Rate, Low Power
Mode (T
Output Data
Rate (Hz)
400
200
100
50
25
12.5
Auto Sleep Mode
Additional power can be saved if the
switches to sleep mode during periods of inactivity. To enable
this feature, set the THRESH_INACT register (Address 0x25)
and the TIME_INACT register (Address 0x26) each to a value
that signifies inactivity (the appropriate value depends on the
application), and then set the AUTO_SLEEP bit and the link bit in
the POWER_CTL register (Address 0x2D). Current consumption
at the sub-8 Hz data rates used in this mode is typically 40 µA
for a V
Standby Mode
For even lower power operation, standby mode can be used. In
standby mode, current consumption is reduced to 0.1 µA (typical).
In this mode, no measurements are made. Standby mode is entered
by clearing the measure bit (Bit 3) in the POWER_CTL register
(Address 0x2D). Placing the device into standby mode preserves
the contents of FIFO.
S
of 2.5 V.
A
= 25°C, V
Bandwidth (Hz)
200
100
50
25
12.5
6.25
S
= 2.5 V, V
DD I/O
ADXL350
= 1.8 V)
Rate Code
1100
1011
1010
1001
1000
0111
automatically
ADXL350
I
100
65
55
50
40
40
DD
(µA)

Related parts for EVAL-ADXL350Z-S