ADP5586CB-EVALZ Analog Devices, ADP5586CB-EVALZ Datasheet - Page 11

no-image

ADP5586CB-EVALZ

Manufacturer Part Number
ADP5586CB-EVALZ
Description
Interface Development Tools
Manufacturer
Analog Devices
Type
I/O Expansionr
Series
ADP5586r
Datasheet

Specifications of ADP5586CB-EVALZ

Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
ADP5586
Interface Type
I2C
Operating Supply Voltage
1.65 V to 3.6 V
Description/function
Evaluation board for keypad decoder and I/O expander
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Current
30 uA
For Use With
ADP5586
Data Sheet
Figure 10 shows a detailed representation of the key scan block
and its associated control and status signals. When all row and
column pins are used, a matrix of 25 unique keys can be scanned.
Use the PIN_CONFIG_A[5:0] and PIN_CONFIG_B[4:0] registers
(Register 0x3A and Register 0x3B, respectively) to configure the
I/Os for keypad decoding. The number label on each key switch
represents the event identifier that is recorded if that switch is
pressed. If all row/column pins are configured, it is possible to
observe all 25 key identifiers on the FIFO.
If a smaller 2 × 2 matrix is configured, for example, by using the
C2 and C3 column pins and the R1 and R2 row pins, only four
event identifiers (8, 9, 13, and 14) can possibly be observed on
the FIFO, as shown in Figure 10.
By default, the
FIFO. Figure 11 illustrates what happens when a single key is
pressed and released. Initially, the key scanner is idle. When Key 3
is pressed, the scanner begins scanning through all configured
row/column pairs. After the scan wait time, the scanner again
scans through all configured row/column pairs and detects that
Key 3 has remained pressed, which sets the EVENT_INT interrupt
bit (Register 0x01, Bit 0). The event counter, EC[4:0] (Register 0x02,
Bits[4:0]), is then incremented to 1; EVENT1_IDENTIFIER[6:0]
of the FIFO is updated with its event identifier set to 3; and its
EVENT1_STATE bit is set to 1, indicating a key press.
ADP5586
records key presses and releases on the
RESET_TRIG_TIME[3:0]
RESET_EVENT_A[7:0]
RESET_EVENT_B[7:0]
RESET_EVENT_C[7:0]
PIN_CONFIG_A[7:0]
PIN_CONFIG_B[7:0]
PIN_CONFIG_C[7:0]
*R5 AVAILABLE ON ADP5586ACBZ-01-R7 ONLY.
31
32
33
34
35
36
C0 C1 C2 C3 C4
11
16
21
26
6
1
12
17
22
27
7
2
SINK ON/OFF
13
18
23
28
COLUMN
8
3
I/O CONFIGURATION
Figure 10. Detailed Key Scan Block
14
19
24
29
4
9
KEY SCAN
CONTROL
10
15
20
25
30
5
Rev. 0 | Page 11 of 44
R0
SENSE
ROW
R1 R2
LOGIC EVENT
KEY EVENT
GPI EVENT
I
2
C BUSY?
R3
RESET_INITIATE
EVENT_INT
R4 R5*
The key scanner continues the scan/wait cycles while the key
remains pressed. If the scanner detects that the key has been
released for two consecutive scan cycles, the event counter,
EC[4:0], is incremented to 2, and EVENT2_IDENTIFIER[6:0]
of the FIFO is updated with its event identifier set to 3. The
EVENT2_STATE bit is set to 0, indicating a release. The key
scanner returns to idle mode because no other keys are pressed.
EVENT_INT
KEY SCAN
EC[4:0]
KEY 3
UPDATE
FIFO
KEY 3 RELEASE
KEY 3 PRESS
Figure 11. Press and Release Event
OVRFLOW_INT
EC[4:0]
FIFO
1
0
0
0
FIFO
3
3
0
0
1
ADP5586
2

Related parts for ADP5586CB-EVALZ