VND810MSP STMicroelectronics, VND810MSP Datasheet - Page 17

no-image

VND810MSP

Manufacturer Part Number
VND810MSP
Description
IC DRVR HISIDE 2CH POWERSO10
Manufacturer
STMicroelectronics
Type
High Sider
Datasheet

Specifications of VND810MSP

Input Type
Non-Inverting
Number Of Outputs
2
On-state Resistance
150 mOhm
Current - Peak Output
900mA
Voltage - Supply
5.5 V ~ 36 V
Mounting Type
Surface Mount
Package / Case
PowerSO-10 Exposed Bottom Pad
Supply Voltage (min)
5.5 V
Supply Current
40 mA
Maximum Power Dissipation
52000 mW
Maximum Operating Temperature
+ 150 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Current - Output / Channel
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VND810MSP
Manufacturer:
ST
0
Part Number:
VND810MSP-E
Manufacturer:
AD
Quantity:
450
Part Number:
VND810MSP13TR
Manufacturer:
ST
0
Part Number:
VND810MSPTR-E
Manufacturer:
ST
Quantity:
1 400
Part Number:
VND810MSPTR-E
Manufacturer:
ST
0
VND810MSP
3.1.2
3.2
3.3
Please note that, if the microprocessor ground is not shared by the device ground, then the
R
values. This shift will vary depending on how many devices are ON in the case of several
high-side drivers sharing the same R
If the calculated power dissipation requires the use of a large resistor, or several devices
have to share the same resistor, then ST suggests using solution 2 below.
Solution 2: a diode (D
A resistor (R
an inductive load. This small signal diode can be safely shared amongst several different
HSD. Also in this case, the presence of the ground network will produce a shift (j600mV) in
the input threshold and the status output values if the microprocessor ground is not common
with the device ground. This shift will not vary if more than one HSD shares the same
diode/resistor network. Series resistor in INPUT and STATUS lines are also required to
prevent that, during battery voltage transient, the current exceeds the Absolute Maximum
Rating. Safest configuration for unused INPUT and STATUS pin is to leave them
unconnected.
Load dump protection
D
V
line that are greater than those shown in the ISO T/R 7637/1 table.
MCU I/O protection
If a ground protection network is used and negative transients are present on the V
the control pins will be pulled negative. ST suggests to insert a resistor (R
prevent the µC I/O pins from latching up.
The value of these resistors is a compromise between the leakage current of µC and the
current required by the HSD I/Os (Input levels compatibility) with the latch-up limit of µC
I/Os:
Example
For the following conditions:
Recommended values are:
CC
GND
ld
is necessary (voltage transient suppressor) if the load dump peak voltage exceeds the
maximum DC rating. The same applies if the device is subject to transients on the V
- V
V
I
V
5k
R
latchup
will produce a shift (I
OH C
CCpeak
prot
CCpeak
R
= 10k
prot
GND
= - 100V
4.5V
20mA
/ I
latchup
65k .
= 1k ) should be inserted in parallel to D
R
prot
S(on)max
GND
(V
OH C
) in the ground line
* R
GND
- V
GND
IH
.
) in the input thresholds and the status output
- V
GND
) / I
IHmax
GND
if the device will be driving
Application information
prot
) in line to
CC
line,
17/27
CC

Related parts for VND810MSP