LFDAS12XSFT Freescale Semiconductor, LFDAS12XSFT Datasheet - Page 302

no-image

LFDAS12XSFT

Manufacturer Part Number
LFDAS12XSFT
Description
HARDWARE MC9S12XS 80-PIN
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of LFDAS12XSFT

Module/board Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
-
Freescale’s Scalable Controller Area Network (S12MSCANV3)
1. Read: Anytime
302
RXFRM
CSWAI
Write: Anytime when out of initialization mode; exceptions are read-only RXACT and SYNCH, RXFRM (which is set by the
module only), and INITRQ (which is also writable in initialization mode)
WUPE
SYNCH
RXACT
Field
TIME
7
6
5
4
3
2
(4)
(3)
(1)
Received Frame Flag — This bit is read and clear only. It is set when a receiver has received a valid message
correctly, independently of the filter configuration. After it is set, it remains set until cleared by software or reset.
Clearing is done by writing a 1. Writing a 0 is ignored. This bit is not valid in loopback mode.
0 No valid message was received since last clearing this flag
1 A valid message was received since last clearing of this flag
Receiver Active Status — This read-only flag indicates the MSCAN is receiving a message. The flag is
controlled by the receiver front end. This bit is not valid in loopback mode.
0 MSCAN is transmitting or idle
1 MSCAN is receiving a message (including when arbitration is lost)
CAN Stops in Wait Mode — Enabling this bit allows for lower power consumption in wait mode by disabling all
the clocks at the CPU bus interface to the MSCAN module.
0 The module is not affected during wait mode
1 The module ceases to be clocked during wait mode
Synchronized Status — This read-only flag indicates whether the MSCAN is synchronized to the CAN bus and
able to participate in the communication process. It is set and cleared by the MSCAN.
0 MSCAN is not synchronized to the CAN bus
1 MSCAN is synchronized to the CAN bus
Timer Enable — This bit activates an internal 16-bit wide free running timer which is clocked by the bit clock rate.
If the timer is enabled, a 16-bit time stamp will be assigned to each transmitted/received message within the
active TX/RX buffer. Right after the EOF of a valid message on the CAN bus, the time stamp is written to the
highest bytes (0x000E, 0x000F) in the appropriate buffer (see
Storage”). The internal timer is reset (all bits set to 0) when disabled. This bit is held low in initialization mode.
0 Disable internal MSCAN timer
1 Enable internal MSCAN timer
Wake-Up Enable — This configuration bit allows the MSCAN to restart from sleep mode or from power down
mode (entered from sleep) when traffic on CAN is detected (see
bit must be configured before sleep mode entry for the selected function to take effect.
0 Wake-up disabled — The MSCAN ignores traffic on CAN
1 Wake-up enabled — The MSCAN is able to restart
The CANCTL0 register, except WUPE, INITRQ, and SLPRQ, is held in the
reset state when the initialization mode is active (INITRQ = 1 and
INITAK = 1). This register is writable again as soon as the initialization
mode is exited (INITRQ = 0 and INITAK = 0).
Table 11-3. CANCTL0 Register Field Descriptions
S12XS Family Reference Manual, Rev. 1.11
2
NOTE
Description
Section 11.3.3, “Programmer’s Model of Message
Section 11.4.5.5, “MSCAN Sleep
(2)
Freescale Semiconductor
Mode”). This

Related parts for LFDAS12XSFT