Z8F0213PJ005SC Zilog, Z8F0213PJ005SC Datasheet - Page 81

IC ENCORE MCU FLASH 2K 28DIP

Z8F0213PJ005SC

Manufacturer Part Number
Z8F0213PJ005SC
Description
IC ENCORE MCU FLASH 2K 28DIP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F0213PJ005SC

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
24
Program Memory Size
2KB (2K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
28-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Data Converters
-
Other names
269-3461
PS024314-0308
Caution:
COMPARATOR COUNTER Mode
In COMPARATOR COUNTER mode, the timer counts input transitions from the analog
comparator output. The TPOL bit in the Timer Control Register selects whether the count
occurs on the rising edge or the falling edge of the comparator output signal. In
COMPARATOR COUNTER mode, the prescaler is disabled.
After reaching the Reload value stored in the Timer Reload High and Low Byte registers,
the timer generates an interrupt, the count value in the Timer High and Low Byte registers
is reset to
enabled, the Timer Output pin changes state (from Low to High or from High to Low) at
timer Reload.
Follow the steps below for configuring a timer for COMPARATOR COUNTER mode and
initiating the count:
1. Write to the Timer Control register to:
2. Write to the Timer High and Low Byte registers to set the starting count value. This
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
5. If using the Timer Output function, configure the associated GPIO port pin for the
6. Write to the Timer Control register to enable the timer.
In COMPARATOR COUNTER mode, the number of comparator output transitions since
the timer start is given by the following equation:
The frequency of the comparator output signal must not exceed one-fourth the system
clock frequency.
action only affects the first pass in COMPARATOR COUNTER mode. After the first
timer Reload in COMPARATOR COUNTER mode, counting always begins at the
reset value of
High and Low Byte registers must be written with the value
to the relevant interrupt registers.
Timer Output alternate function.
Comparator Output Transitions
Disable the timer.
Configure the timer for COMPARATOR COUNTER mode.
Select either the rising edge or falling edge of the comparator output signal for the
count. This also sets the initial logic level (High or Low) for the Timer Output
alternate function. However, the Timer Output function is not required to be
enabled.
0001H
and counting resumes. Also, if the Timer Output alternate function is
0001H
. Generally, in COMPARATOR COUNTER mode the Timer
=
Current Count Value Start Value
Z8 Encore! XP
Product Specification
0001H
.
®
F0823 Series
Timers
71

Related parts for Z8F0213PJ005SC