CYWUSB6935-48LFXC Cypress Semiconductor Corp, CYWUSB6935-48LFXC Datasheet - Page 12

no-image

CYWUSB6935-48LFXC

Manufacturer Part Number
CYWUSB6935-48LFXC
Description
IC USB WIRELESS 2.4GHZ 48VQFN
Manufacturer
Cypress Semiconductor Corp

Specifications of CYWUSB6935-48LFXC

Frequency
2.4GHz
Data Rate - Maximum
62.5kbps
Modulation Or Protocol
DSSS, GFSK
Applications
AMR, ISM, RKE
Power - Output
0dBm
Sensitivity
-95dBm
Voltage - Supply
2.7 V ~ 3.6 V
Current - Receiving
57.7mA
Current - Transmitting
69.1mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
0°C ~ 70°C
Package / Case
48-VQFN Exposed Pad, 48-HVQFN, 48-SQFN, 48-DHVQFN
Transmitting Current
69.1mA
Data Rate
62.5Kbps
Frequency Range
2.4GHz To 2.483GHz
Modulation Type
GFSK
Rf Ic Case Style
QFN
No. Of Pins
48
Supply Voltage Range
2.7V To 3.6V
Operating
RoHS Compliant
Sensitivity Dbm
-95dBm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
428-1625

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CYWUSB6935-48LFXC
Manufacturer:
MICRON
Quantity:
1 001
Part Number:
CYWUSB6935-48LFXC
Manufacturer:
CIRRUS
Quantity:
20 000
Document 38-16008 Rev. *A
Bit
7
6
5
4
3
2
1
0
Underflow B
Name
Underflow B
Overflow B
EOF B
Full B
Underflow A
Overflow A
EOF A
Full A
7
Addr: 0x07
Overflow B
Description
The Underflow B bit is used to enable the interrupt associated with an underflow condition with the Receive SERDES
Data B register (Reg 0x0B)
An underflow condition occurs when attempting to read the Receive SERDES Data B register (Reg 0x0B) when it is
empty.
The Overflow B bit is used to enable the interrupt associated with an overflow condition with the Receive SERDES
Data B register (Reg 0x0B)
An overflow condition occurs when new received data is written into the Receive SERDES Data B register (Reg
0x0B) before the prior data is read out.
The End of Frame B bit is used to enable the interrupt associated with the Channel B Receiver EOF condition.
The EOF IRQ asserts during an End of Frame condition. End of Frame conditions occur after at least one bit has
been detected, and then the number of invalid bits in the frame exceeds the number in the EOF length field. If 0 is
the EOF length, and EOF condition will occur at the first invalid bit after a valid reception. This IRQ is cleared by
reading the receive status register
The Full B bit is used to enable the interrupt associated with the Receive SERDES Data B register (Reg 0x0B) having
data placed in it.
A Full B condition occurs when data is transferred from the Channel B Receiver into the Receive SERDES Data B
register (Reg 0x0B). This could occur when a complete byte is received or when an EOF event occurs whether or
not a complete byte has been received.
The Underflow A bit is used to enable the interrupt associated with an underflow condition with the Receive SERDES
Data A register (Reg 0x09)
An underflow condition occurs when attempting to read the Receive SERDES Data A register (Reg 0x09) when it is
empty.
The Overflow A bit is used to enable the interrupt associated with an overflow condition with the Receive SERDES
Data A register (0x09)
An overflow condition occurs when new receive data is written into the Receive SERDES Data A register (Reg 0x09)
before the prior data is read out.
The End of Frame A bit is used to enable the interrupt associated with an End of Frame condition with the Channel
A Receiver.
The EOF IRQ asserts during an End of Frame condition. End of Frame conditions occur after at least one bit has
been detected, and then the number of invalid bits in a frame exceeds the number in the EOF length field. If 0 is the
EOF length, an EOF condition will occur at the first invalid bit after a valid reception. This IRQ is cleared by reading
the receive status register.
The Full A bit is used to enable the interrupt associated with the Receive SERDES Data A register (0x09) having
data written into it.
A Full A condition occurs when data is transferred from the Channel A Receiver into the Receive SERDES Data A
register (Reg 0x09). This could occur when a complete byte is received or when an EOF event occurs whether or
not a complete byte has been received.
1 = Underflow B interrupt enabled for Receive SERDES Data B
0 = Underflow B interrupt disabled for Receive SERDES Data B
1 = Overflow B interrupt enabled for Receive SERDES Data B
0 = Overflow B interrupt disabled for Receive SERDES Data B
1 = EOF B interrupt enabled for Channel B Receiver
0 = EOF B interrupt disabled for Channel B Receiver
1 = Full B interrupt enabled for Receive SERDES Data B
0 = Full B interrupt disabled for Receive SERDES Data B
1 = Underflow A interrupt enabled for Receive SERDES Data A
0 = Underflow A interrupt disabled for Receive SERDES Data A
1 = Overflow A interrupt enabled for Receive SERDES Data A
0 = Overflow A interrupt disabled for Receive SERDES Data A
1 = EOF A interrupt enabled for Channel A Receiver
0 = EOF A interrupt disabled for Channel A Receiver
1 = Full A interrupt enabled for Receive SERDES Data A
0 = Full A interrupt disabled for Receive SERDES Data A
6
EOF B
5
Figure 7-8. Receive SERDES Interrupt Enable
Full B
REG_RX_INT_EN
4
Underflow A
3
Overflow A
2
EOF A
1
CYWUSB6935
Default: 0x00
Page 12 of 32
Full A
0

Related parts for CYWUSB6935-48LFXC