ACPL-K342-060E Avago Technologies US Inc., ACPL-K342-060E Datasheet - Page 4

Logic Output Optocouplers Optocoupler

ACPL-K342-060E

Manufacturer Part Number
ACPL-K342-060E
Description
Logic Output Optocouplers Optocoupler
Manufacturer
Avago Technologies US Inc.
Series
-r
Type
Gate Driver, Miller Clampr
Datasheet

Specifications of ACPL-K342-060E

Fall Time
18 ns
Rise Time
22 ns
Maximum Propagation Delay Time
0.35 us
Maximum Forward Diode Voltage
1.95 V
Minimum Forward Diode Voltage
1.2 V
Maximum Reverse Diode Voltage
5 V
Maximum Continuous Output Current
2.5 A
Maximum Power Dissipation
255 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Package / Case
SOIC-8
No. Of Channels
1
Isolation Voltage
5kV
Optocoupler Output Type
Gate Drive
Input Current
230mA
Output Voltage
30V
Opto Case Style
SOIC
No. Of Pins
8
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Voltage - Isolation
5000Vrms
Input Type
DC
Voltage - Supply
15 V ~ 30 V
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-H342 / ACPL-K342 is approved by the following organizations:
UL
Recognized under UL 1577, component recognition program up to V
(ACPL-K342), File 55361
CSA
CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-5 (ACPL-H342/K342 Option 060 Only)
Maximum Working Insulation Voltage Viorm = 891V
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-H342 / ACPL-K342 Option 060)
*
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802.
4
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Input to Output Test Voltage, Method a*
V
Highest Allowable Overvoltage*
(Transient Overvoltage t
Safety-limiting values – maximum values allowed in the event of a failure,
also see Figure 37.
Insulation Resistance at T
IORM
IORM
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
for rated mains voltage d 150 V
for rated mains voltage d 300 V
for rated mains voltage d 450 V
for rated mains voltage d 600 V
for rated mains voltage d 1000 V
Case Temperature
Input Current
Output Power
x 1.875=V
x 1.6=V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
ini
S
, V
= 60 sec)
IO
= 500 V
rms
rms
rms
rms
rms
m
=10 sec, Partial discharge < 5 pC
m
=1 sec, Partial discharge < 5 pC
peak
(ACPL-H342) and Viorm = 1140 V
ISO
= 3750 V
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
S, OUTPUT
S
IORM
PR
PR
IOTM
RMS
(ACPL-H342) and V
ACPL-H342
Option 060
I – IV
I – IV
I – III
I – III
55/100/21
2
891
1671
1426
6000
175
230
600
>10
peak
9
(ACPL-K342)
ACPL-K342
Option 060
I – IV
I – IV
I – IV
I – IV
I – III
55/100/21
2
1140
2137
1824
8000
175
230
600
>10
ISO
9
= 5000 V
Unit
V
V
V
V
°C
mA
mW
:
peak
peak
peak
peak
RMS

Related parts for ACPL-K342-060E