LIS3LV02DQ STMicroelectronics, LIS3LV02DQ Datasheet - Page 34

ACCELEROMETER TRPL AXIS 28QFPN

LIS3LV02DQ

Manufacturer Part Number
LIS3LV02DQ
Description
ACCELEROMETER TRPL AXIS 28QFPN
Manufacturer
STMicroelectronics
Datasheet

Specifications of LIS3LV02DQ

Axis
X, Y, Z
Acceleration Range
±2g, 6g
Sensitivity
1024LSB/g, 340LSB/g
Voltage - Supply
2.16 V ~ 3.6 V
Output Type
Digital
Bandwidth
40Hz ~ 2.56kHz Selectable
Interface
I²C, SPI
Mounting Type
Surface Mount
Package / Case
28-QFN
Sensing Axis
X, Y, Z
Acceleration
2 g, 6 g
Digital Output - Number Of Bits
12 bit, 16 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Supply Current
0.6 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Body Style
QFPN
Function
Accelerometer
Primary Type
Accelerometer
Range, Measurement
2/6 g
Voltage, Supply
3.6 V
No. Of Axes
3
Ic Interface Type
I2C, SPI
Sensor Case Style
QFN
No. Of Pins
28
Supply Voltage Range
2.16V To 3.6V
Operating Temperature Range
-40°C To +85°C
Rohs Compliant
Yes
For Use With
497-6249 - BOARD EVAL ACCEL DGTL LIS3LV02DQ497-5069 - EVAL BOARD 3AXIS MEMS ACCELLRMTR
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-4919

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LIS3LV02DQ
Quantity:
5 510
Part Number:
LIS3LV02DQ
Manufacturer:
ST
0
Part Number:
LIS3LV02DQ
Manufacturer:
ST
Quantity:
20 000
Part Number:
LIS3LV02DQ-TR
Quantity:
1 679
Part Number:
LIS3LV02DQ-TR
Manufacturer:
ST
0
Part Number:
LIS3LV02DQ-TR
Manufacturer:
ST
Quantity:
20 000
Part Number:
LIS3LV02DQTR
Manufacturer:
ST
0
Part Number:
LIS3LV02DQTR
Manufacturer:
ST
Quantity:
20 000
7 Register Description
7.25
34/42
DD_CFG (38h)
Direction-detector configuration register
IEND
LIR
ZHIE
ZLIE
YHIE
YLIE
XHIE
XLIE
Interrupt enable on Direction change. Default value: 0
(0: disabled;
1: interrupt signal enabled)
Latch Interrupt request into DD_SRC reg with the DD_SRC reg cleared by reading
DD_ACK reg. Default value: 0.
(0: interrupt request not latched;
1: interrupt request latched)
Enable interrupt generation on Z high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
IEND
LIR
ZHIE
CD00047926
ZLIE
YHIE
YLIE
XHIE
XLIE
LIS3LV02DQ